Filter Results By:
Products
Applications
Manufacturers
-
product
High Precision Rotation Luminaire Goniophotometer
LSG-1800B
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Goniometer Systems
Our Goniometetric measurement systems are optimized to provide precise measurement of angle dependent spatial radiation properties of LED luminaires, lamps and other light-producing modules. Using a variety of photometric and spectroradiometric detector options, our goniometer systems achieve optical properties as a function of angle with accuracy, precision and speed.
-
product
Total Flux Measurement Systems
LED’s and Luminaires must be characterized and tested for brightness and color, for production quality control and also for R&D. The Gamma Scientific Total Flux Measurement System combines our accurate Radoma Spectrometer and an integrating sphere for total flux (total power) and color measurements of LED, micro LED and Luminaires. Measurement parameters include spectrum, lumens, total power, peak and dominant wavelength, CRI, CCT, FWHM and other optical properties.
-
product
IEC60529 IPX7 Water Immersion Test Chamber
Shenzhen Chuangxin Instruments Co., Ltd.
This device is designed and manufactured accordance with requirements of IEC 60529 and GB4208-2008
IPX7 level. Applied to waterproof test of luminaire and household appliance. -
product
Spectroradiometer
CAS 140CT IR
Instrument Systems Optische Messtechnik GmbH
Manufacturers of high-class LEDs, luminaires and displays all over the world have for many years been placing their trust in the precise and reliable measuring results of the CAS array spectroradiometer from Instrument Systems.
-
product
Goniophotometer
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
product
IK Level Tester
IK07-10
IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
product
Integrating Spheres
IP-Series
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
product
General Lighting & Luminaire Goniophotometers
Photometric Solutions International Pty Ltd
These are Type C/gamma goniophotometers with wide-ranging applications including luminaires, floodlights, streetlights, LED clusters, emergency lighting, flat panel displays and others. These goniophotometers typically have an angular accuracy of better than 0.1°, which is perfect for LED and luminaire goniophotometry. The control software that comes with each system has advanced functions that make testing easy – even for inexperienced users. Additionally, the report generator and other software utilities that are also supplied make these systems powerful and advanced research and development tools.
-
product
LT-500A Aging-Life Test System For LED Luminaires
Hangzhou Everfine Photo-E-Info Co., LTD
LT-500A system is widely used for normal /accelerated aging, lumen maintenance measuring, chromaticity shift measuring, lifetime evaluation and temperature characteristic testing for LED luminaires, arrays, and modules. The extrapolation of lifetime by programmable models is also available to estimate the lifetime of LED luminaires.
-
product
Spring Impact Hammer IK Level Tester
IK01-06
The most of luminaires manufactory were request to do IK level test (Impact Protection), LISUN can supply the IK test instrument. IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
product
Measuring System for Assessment of Optical Radiation Safety
IEC62471
The system is designed especially for the determination of optical radiation hazard exposures specified in IEC62471, such as actinic UV hazard exposure for the skin and eye, near-UV hazard exposure for the eye, retinal blue light hazard exposure, retinal thermal hazard exposure, thermal radiation hazard for eye and skin, for LED products, UV-Lamps, lighting sources, luminaires and etc.
-
product
LT-300A Aging-Life Test System For LED Luminaires
Hangzhou Everfine Photo-E-Info Co., LTD
LT-300A system is widely used for normal /accelerated aging, lumen maintenance measuring, chromaticity shift measuring, lifetime evaluation and temperature characteristic testing for LED luminaires, arrays, and modules. The extrapolation of lifetime by programmable models is also available to estimate the lifetime of LED luminaires.
-
product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
LM-79 Moving Detector Goniophotometer
LSG-5000
Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
-
product
Compression Test Apparatus
CT-20 C
Is designed to perform tests specified in many standards where resistance of insulating materials to elevated operating temperatures is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaires, motors, connectors, etc. The test ensures that external parts of insulating material, the deterioration of which might cause the appliance to fail to comply with the relevant standards, are sufficiently resistant to heat
-
product
Conversion Kit for Kelvin Holders
KC-4
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary
-
product
Leakage Current Tester
TOS3200
The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment.It enables you to conduct tests that conform to the requirements of the applicable IEC, UL, JIS, and other standards, as well as the Electrical Appliance and Material Safety Law. The memory in the main unit stores the 51 types of test conditions laid down in the IEC/JIS standards for information technology equipment, household electrical appliances, audio, video electronic apparatus, luminaires, motor-operated electric tools, and electrical equipment for measurement and control and in the Electrical Appliance and Material Safety Law, thereby enabling you to conduct standard tests with simple panel operation.
-
product
Lighting Reliability
LED/OLED package lifetime is highly dependent on thermal management, and LED lamp performance can be dependent on the luminaire in which it is installed. Lighting reliability test system for LED/OLED Products are widely used for normal /accelerated aging, lumen maintenance measuring, lifetime evaluation and temperature characteristic testing for LED/OLED products including LED package, array, module, OLED module and luminaires.
-
product
Horticulture Meters
Cultivate and preserve healthy plants using the Solarmeter® GrowMeters, and Solar Light’s Digital and/ or Analog Quantum Light (PAR) calibrated sensors. Our point-and-click NIST-traceable meters are used to monitor lamp intensity and aging for horticultural applications. By measuring the intensity of luminaires and grow lights, these meters will ensure lamps are performing as needed to produce healthy valuable crops.
-
product
Near Field Moving Detector Goniophotometer
LSG-1900B
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
-
product
Compact Goniophotometer For Lamp Spread Angle Tester
Shenzhen Chuangxin Instruments Co., Ltd.
LCG-1600 Goniophotometrc System carries out measuring methods of fixed location and rotating luminaires. The measured luminaire is installed on the two-dimension rotating table, using “+” laser to make the luminaire lighting center superposed with the rotating center of rotating table. The mechanical equipment allows turning the tested luminaires around a vertical axis and a horizontal axis. When tested luminaires turn around horizontal axis, the detector which is at the same level with rotating table will measure the intensity of each direction at this surface. When rotating with vertical axis, the detector will measure the intensity at the vertical surface. The vertical and horizontal axis can be rotated continuously at ±180° or 0~360°. According to the measurement requirements, the system can be operated in C-γ coordinates. When getting intensity distribution data, computer will calculate other photometric parameters automatically.
-
product
Safety
Test Equipment to verify Safety, Quality and Compliance characteristics of electro-technical products as required by national and international safety regulatory agencies. These equipment are used to check Electrical Wiring Accessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Several of these safety test equipment are common to many standards and are required for routine 100% test purposes to ensure product safety.
-
product
Near-field Goniophotometer
RiGO801
TechnoTeam Bildverarbeitung GmbH
Correct determination of the luminous intensity distributions (lid) of lamps and luminaires far within their photometric near-field range. Capture of ray data.
-
product
Light Distribution Photometer Goniophotometer
LCG-1600
Shenzhen Chuangxin Instruments Co., Ltd.
LCG-1600 Goniophotometeric System carries out measuring methods of fixed location and rotating luminaires. The measured luminaire is installed on the two-dimension rotating table, using “+” laser to make the luminaire lighting center superposed with the rotating center of rotating table. The mechanical equipment allows turning the tested luminaires around a vertical axis and a horizontal axis. When tested luminaires turn around horizontal axis, the detector which is at the same level with rotating table will measure the intensity of each direction at this surface. When rotating with vertical axis, the detector will measure the intensity at the vertical surface. The vertical and horizontal axis can be rotated continuously at ±180° or 0~360°. According to the measurement requirements, the system can be operated in C-γ coordinates. When getting intensity distribution data, computer will calculate other photometric parameters automatically.
-
product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
product
Goniophotometer For Luminaries Intensity Distribution Curve
LCG-1800
Shenzhen Chuangxin Instruments Co., Ltd.
Mainly used to measure FL etc. When installing luminaires, the lighting center of luminare and the rotating center of rotating table shall be at the same position. In B- coordinates, luminaire axis is superposed with the horizontal axis of rotating table. In A- coordinates, luminaire axis is vertical with the horizontal axis of rotating table.
-
product
Safety Test Panel for Luminaire Fixture
SCR ELEKTRONIKS introduces Safety Test Panel for Luminaire with PC Datalogging. The tests are Performed as Prescribed in IS the Panel Carries out different tests one by one and provides indication of the Test results as OK or NOT-OK. It is very useful and handy in line testing on Mass production line as well as type Testing.
-
product
Constant Temperature Integrating Sphere
IS-*MT
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Goniophotometers
Instrument Systems Optische Messtechnik GmbH
All goniophotometers are designed as Type C with a horizontal alignment of the optical axis (turning luminaire configuration). Each goniometer sets benchmarks in its class for precision, reliability and handling. If these goniophotometers are combined with a spectroradiometer from Instrument Systems, they are able to determine not only photometric data but also spectral quantities, such as color coordinates, color temperature, and even color rendering index as a function of angle.