Filter Results By:
Products
Applications
Manufacturers
Standards
A controlled reference or acknowledged technical criterion.
See Also: IEC, IEEE, Mil, Interoperability Test, Compliance
- Virginia Panel Corporation
product
Mounting Panel, ICon, 6U, 4 Positions, With Slide Mounting (slide Kit Required)
310113540
The 6U Slide-Mounted Plate mounts to standard 19" racks and slides open to allow access to wiring between the instruments and VPC iCon receivers. The 4 cutouts are spaced evenly across the panel. iCon cover plate is sold separately (310 113 467). This mounting plate is designed to work with a slide kit and includes flanges and an instrument bracket. A slide kit is required for use.
-
product
Cup, Concave 90/120°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0A
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Standard Control and Alarm Panel
8040
From our range of B/W Controls products we can supply the 8040 Series control panel with control relay, wired terminal block, motor starter, or a panel for just the external connections.Included in the 8040 Series standard control and alarm panel is the B/W system wiring diagram which assures quick and easy installation and the confidence that the system will work right the first time.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2D
Current Rating (Amps): 5Average Probe Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64Resistance (mOhm): 35
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I40-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Battery Extra Load Units
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
product
Rain Test Chambers
Shanghai Morningtest Environmental Chambers Co.,Ltd.
Rain test chambers for ingress protection testing simulates rain/water test as per IEC 60529 and DIN 40050-9((IP Code standard)) test standard. • IPX1 Protection against vertically dripping water• IPX2 Dripping water ± 15° from vertical• IPX3 Protection against spraying water• IPX4 Protection against splashing water• IPX5 Protection against low pressure jetting water• IPX6 Protection against high pressure jetting water• IPX7 Protection against temporary immersion• IPX8 Protection against continuous immersion• IPX9K Extremely high pressure jetting water
-
product
Dilution / Sampling Systems
HORIBA offer a full range of full flow CVS and partial flow systems for exhaust gas measurement that cover the requirements of all of the global emissions standards. These are complemented by a full range of solutions for the measurement of particulate mass and particulate number required to meet the latest legislative standards.
-
product
CDPH Standard Method for VOC Emissions
Underwriters Laboratories Inc.
The Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions From Indoor Sources Using Environmental Chambers, an expanded standard for what is commonly known as California Specification 01350, is one of the most widely used standards to evaluate building and interior products for low chemical emissions.
-
product
EDXIR-Analysis Contaminant Finder/Material Inspector
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues identification results and the degree of matching. it can also be used to perform EDX or FTIR data analysis on its own. The library used for data analysis (containing 485 data as standard) is original to Shimadzu, and was created through cooperation with water supply agencies and food manufacturers. Additional data can be registered to the library, as can image files and document files in PDF format. It is also effective for the linked storage of various types of data as electronic files.
-
product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-2W1S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
ISO/ANSI Compliance
The ANSI and ISO/IEC standard for the C Programming Language specifies that there are two forms of conforming compiler implementations: hosted and freestanding.
-
product
Constant Flow Pump
Supercritical 24
The Supercritical 24 Constant Flow Pump is designed to be a reliable component wherever a constant flow must be maintained. The flow rate of the Supercritical 24 pump fitted with two standard 12 mL pump heads can be set in 0.01 mL/min increments from 0.00 to 24.0 mL/min.The Supercritical 24 Constant Pressure pump is designed to be a reliable component wherever a constant pressure must be maintained. Pressure can be set in 10-psi increments from 0 to 10,000 psi.
-
product
Renesas Synergy™ Microcontrollers
S3 Series - High Efficiency
Stretch application efficiency with optimized power for performance in the S3 Series. Handle data-intensive operations with minimal CPU clock cycles and a built-in Floating -Point Unit for data security with features such as Advanced Encryption Standard (AES), True Random Number Generator (TRNG), and Memory Protection Unit (MPU).
-
product
SpaceWire Monitors
This section details the 4Links range of high-performance test equipment that is used to monitor SpaceWire networks. These devices are attached to your SpaceWire systems and then can be accessed via Gigabit Ethernet, using the standard TCP/IP family of protocols, so that they can be controlled remotely (for instance, by partners collaborating on a mission).
-
product
Calibration Hangers And Weights
Calibrated Dead Weight are the official means by which torque analyzers and torque sensors are calibrated and are traced to National or International Standards, such as N.I.S.T, ISO and others. Many industries like as medical, aerospace, nuclear and others continuously calibrate their measuring equipment to comply with government regulations. For companies that prefer to have calibration capabilities in-house when their calibration requirements become extensive, they need calibration equipment.
-
product
Comb Generator, 10 MHz To 110 GHz
U9391M
U9391M comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
product
6-12V LED Computer-safe Circuit Tester
1673
Peaceful Thriving Enterprise Co Ltd
Check on 6-12V systems. Safely test standard primary automotive circuit and on-board computer controlled electrical system without damaging the micro-processor.
-
product
Resistance
Ohmmeters, decade boxes and resistance standards for tests against safety and quality.
-
product
ISTA Testing
ISTA is an organization focused on the specific concerns of transport packaging and whose mission is to develop and deliver standards, educational programs and tools for the economic, social, and environmental optimization of packaging systems. ISTA testing is a well defined shipping testing procedure designed to verify that your packaging is sufficient to protect your product during all shipping environments.
-
product
Automatic and Accurate Inspecting Systems
Circuit AOI
The Circuit AOI system is designed to perform automatic and accurate inspecting systems. It integrates rigid mechanical system with advanced vision technology and manufactured and tested by strict is standards. It is suitable for circuit inspection for PCB/FPC, verification and repair. Innovation and unique inspection algorithms are applied to inspect open, short, protrusion, nick, scratch, pin hole, island, line width/space violation, object missing and others defects. AOI system can use offline setup project and check results. It will improve the throughput.Compare to halogen lighting, the full angle LED lighting of Circuit AOI can obtain the best image contrast and is good for different panel type inspection.
-
product
HV Rotary Switches
B-1003
A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use. In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation. G-7 silicone glass is used for special applications where RF or high temperatures are involved. Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force. This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions. Ratings to 150kV, to 200A. When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater. In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional). Each unit is either manually or electrically operated. One SPDT contact is standard on most units. The auxiliary contact is used as an interlock for protection against "Switching Hot".
-
product
Environmental Chamber
Wewon Environmental Chambers Co, Ltd.
The environmental chamber for conditioning of samples prior to testing, It also can be used for a variety of materials of high – low temperature alternating test. The test for temperature, humidity, time can be programmed. Provides conditions of temperature from -70 degree to +180 degree and of humidity form 10% to 98%.environmental chamber ● The ideal simulation environmental chamber for all heat and cold testing between -70 ºC and 180 ºC temperature range.● Well suited for reliability testing based on current test standard in the temperature range of -70 °C to 180 °C & 10% to 98% RH.● This design SUS environmental chamber meet all requirements for extreme testing and low temperature alternating climate profiles from -70 °C -180 °C with humidity
-
product
Gas Analyzers
Independent Handheld 5 Gas Analyzer or use with MODIS™ Link, VERDICT® and VERUS® Bluetooth® link. Fully Portable 5 Gas Analyzer, go anywhere, use anywhere 110 V AC and 12 V powered Internal rechargeable battery, up to one hour of use Ideal for road testing and mobile use Measures exhaust emissions for CO, CO2, HC, O2, NOx and AFR/Lambda Provides an instant assessment of an engine vehicle exhaust and catalytic converter MODIS, VERDICT® and VERUS® Link for enhanced real-time viewing Setup required with included software on USB stick Gather all the evidence required for effective and accurate vehicle diagnostics on one screen in real time View, graph, save and recall data Monitor and reduce vehicle emissions, improve driveability and fuel efficiency There are 255 memory locations in the analyzer to track and print data for the same or many different vehicles Compatible with gasoline, CNG, propane and diesel fuel types Annual calibration and sensor replacement performed at Crystal Lake Northern Repiar enter Meets required industry standard
-
product
FieldFox Handheld Microwave Analyzer
N9913A
4 GHz max frequency Carry the world's most integrated handheld RF analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without warm-up Calibrate simply with QuickCal Lightest all-in-one analyzer at only6.6 lb. (3.0 kg) Industry-leading 3 year warranty Every spec verified, adjustments included Lock in support & peak performance from the start
-
product
Digital Instantaneous Frequency Measurement Receivers
DIFM
Mercury Systems offers a range of standard high-performance broadband Digital Instantaneous Frequency Measurement (DIFM) receivers and Digital Frequency Discrimination (DFD), which act as functional building blocks in many military electronic warfare systems. Examples include electronic counter measures (ECM) systems, electronic surveillance measures (ESM) systems and radar warning receivers (RWR).
-
product
Bench Mounted Tester
Flex 10
The Flex 10 bench mounted ATE is the smallest ‘standard’ tester in our range. The system comprises a single unit, measuring 600mm x 360mm x 660mm. A VPC S6 interface is normally used on this system allowing multiple test fixtures to be used with the system.
-
product
Bending Deflectometers For ISO 178, JIS K 7171, And ASTM D790 Compliant Testing
After tensile testing, flexural tests are the most common strength tests for plastics and other resins. The main standards for plastic flexural (bend) tests are ISO 178, JIS K 7171, and ASTM D790, which require very accurate test systems. These standards include flexural strain measurements using a deflectometer, ranging from micro-strain measurements in the elastic region, the reversible elongation at the beginning of tests, to larger strain measurements in the plastic region. Shimadzu's deflectometers integrate easily into AG-X plus series, AGS-X series, and EZ-X test frames and Trapezium X testing software. Since these deflectometers push up against the specimen from below, the specimen color is not a limiting factor, as can be for laser type non-contact deflectometers. Furthermore, these deflectometers can partially absorb the shock during specimen failure, preventing specimen fragments from scattering.
-
product
PXI/PXIe USB Data Comms Multiplexer, 16-Channel
42-737A-001
The 40-737A-001 (PXI) and 42-737A-001 (PXIe) are 16:1 USB data communications multiplexers suitable for switching USB1 and USB2 data and power connections using a 78 way D-Type connector. The data signal paths are 2-pole arranged as differential pairs as defined by the USB standard.
-
product
Tilt Switch and Control Unit
MTS / SCU-200
Features • Detects the presence or absence of bulk material • Standard enclosure is NEMA 12 with indicator lights • NEMA 4 and Intrinsically Safe enclosures available • Rugged heliarc-welded steel probes • Use with SCU-200 for complete monitoring system
-
product
PXIe-5665, Up to 14 GHz PXI Vector Signal Analyzer
781774-03
Up to 14 GHz PXI Vector Signal Analyzer - The PXIe‑5665 is a modular, three‑stage superheterodyne analyzer that you can use as either a spectrum analyzer or vector signal analyzer. It supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. In addition, you can use the PXIe‑5665 with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5665 can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5665 provides a low-cost solution to high-performance RF measurements.