Filter Results By:
Products
Applications
Manufacturers
Pre-amplifiers
Detect and strengthen a signal prior to greater amplification.
-
product
Saluki SE4002 FET Input Preamplifier
The SE4002 is a low-noise, ultra-high input impedance preamplifier with excellent common-mode rejection. It is designed to work with any Saluki digital lock-in amplifier. The preamplifier minimizes noise and pickup in the connecting lines and reduces measurement time in noise-limited experiments.
-
product
Shield Level / Pathloss Equipment
SG1000B/PR1000A
The SG1000 Signal Generator and PR1000A Preamplifier have been designed to simplify the measurement of shielding integrity in a shielded enclosure. When coupled with a high stability spectrum analyzer and an appropriate selection of test antennas, the SG1000/PR1000A combination can measure shielding effectiveness at all of the NSA 94-106 (supersedes NSA 65-6) defined test frequencies from 1 kHz to 10 GHz.The PR1000A amplifies the received signal from the test antenna and overcomes the high noise figure of the companion test receiver or spectrum analyzer. The PR1000A will ensure that the system noise figure will be less than 4.5 dB at all test frequencies from 1 kHz to 10 GHz. When used with a spectrum analyzer measurement bandwidth of 100 Hz, the system exhibits a sensitivity of -150 dBm at the test antenna output.To overcome high cable loss between the test antenna and the PR1000A assembly at 10 GHz, a remote low noise pre-amplifier (Praxsym PN 310-010091-001) is mounted directly onto the 10 GHz antenna.
-
product
Externally Polarized Precision Condenser Microphones & Preamplifiers
Externally polarized microphones set the initial standard for all acoustic test and measurement applications. They rely on a dedicated 200V power supply and specialized cables with 7-pin LEMO® connectors. Their straightforward design supports a wide product range. Often chosen as replacements for existing models or when prepolarized alternatives are unavailable.
-
product
60 GHz Noise Figure Test Set
The Noisecom 60 GHz Noise Figure test set has 4 separate systems designed to perform Y-factor noise figure measurements using a high performance Spectrum Analyzer or a dedicated receiver. Each system contains a highly stable V-band noise source, isolator(s), optional waveguide to coaxial transitions and an optional pre-amplifier for use with a spectrum analyzer. The two standard calibration tables have ENR data points at 1 GHz intervals.* System ENR is measured before the DUT connector and at the final output stage allowing for pre-test calibration of the system.
-
product
Preamplifiers
The primary function of a preamplifier is to extract the signal from the detector without significantly degrading the intrinsic signal-to noise ratio. Three basic types of preamplifiers are available: the current-sensitive preamplifier, the parasitic-capacitance preamplifier, and the charge-sensitive preamplifier. ORTEC manufactures a preamplifier to fit your detector, your application, and your budget.
-
product
Miniature AE Sensor With Isolated Integral 30 DB
The Guzik miniature AE sensor with isolated integral 30 dB preamplifier has a wide-band and excellent frequency response over the range of up-to 1 MHz. Its small size makes the sensor ideal for hard disk drive test or similar applications requiring very small size, low weight, wideband AE sensor response and high sensitivity. A small diameter, external flexible cable connects the sensor with a 3-pin JST connector on the other end.
-
product
Low Cost Microwave Wideband PIN Preamp Receivers
MR21 (40KHz~18GHz)
Hangzhou Huatai Optic Tech. Co., Ltd.
MR21 series microwave wideband optical receiver, adopts High linear PIN diode and Low noise pre-amplifier IC, within bandwidth of 40KHz~18GHz, they are featured with excellent linearity, high responsibility and superior flatness of the RF response in both, power and phase. They provide an outstanding linearity fiber optical communication for analogue wideband microwave application. Due to avoidance of using expensive coaxial cable or wave guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless, timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s and 18Gb/s high speed communication system.
-
product
Preamplifiers
LNA Series
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
product
2-Ch Sensor Amplifier
SR-2210
The SR-2210 sensor amplifier accepts constant-current line drive sensors and connects the signal to analyzers and recorders that would not otherwise be compatible with constant-current sensors.The units connects directly with BNC connectors to ONO's model MI-3111 microphone preamplifiers and NP-3000 series of accelerometers.With compact, light-weight, battery operation, it can save for preparation of measurement.
-
product
High Impedance Preamplifier
1671
The Model 1671 is a single ended low noise field effect transistor
-
product
High-Sensitivity Tri-Axial Accelerometer with Built-In Preamplifier
NP-7310
NP-7310 is the accelerometer with built-in preamplifier, and capable of tri–axial directions simultaneous measurement. It is suitable for the low frequency vibration measurement such as ground vibration or floor vibration while operating the machine. NP-7310 can be used with the sensor amplifier unit such as AU-2100, AU-2300 or PS-1300. Also, it is possible to input directly to the analyzer or recorder which the constant current amplifier is built-in such as the FFT Analyzer of DS-2000 series, DS-3000 series, CF-7200A, CF-9000 series or CF-3650/3850 series.
-
product
Energy Probes
RjP-600 Series
The RjP-600 Series energy probes integrate the detector and preamplifier in the same enclosure, thereby maximizing signal integrity between the detector and preamplifier. This permits longer cable runs between the probe and instrument, as is often necessary in production environments. Probe specific information, like calibration date and wavelength response curves, is stored in the probe for access by the instrument. Other features include interchangeable filter holders and ¼-20 mounting hole.
-
product
Lock-In Voltage Preamplifier
SR550
Stanford Research Systems, Inc.
The SR550 Voltage Preamplifier is designed to work with any SRS lock-in amplifier. Preamplifiers provide gain close to the experimental detector, before the signal-to-noise ratio is permanently degraded by cable capacitance and pickup
-
product
PXIe-5668, Up to 26.5 GHz PXI Vector Signal Analyzer
783156-02
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.
-
product
Microphone preamplifier
PRE-01
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
product
PXIe-5668, Up to 26.5 GHz PXI Vector Signal Analyzer
783124-01
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.
-
product
Bias Tees for Radio Amateurs
Bias Tee for remote power supply of preamplifiers and converters via the coaxial cable.
-
product
Energy Probes
RjP-700 Series
The RjP-700 Series probes are designed to measure lower pulse repetition rate, longer duration pulses - up to 1msec pulse width at a maximum rep rate of 40Hz. This allows for measurement of pulsed flashlamps and other sources not possible with other probes. The combination of large area detector surface and long pulse width allow for measurements up to several Joules total energy. Integrated preamplifiers allow for longer probe-to-instrument cable runs, useful for manufacturing environments.
-
product
Preamplifier, 100 MHz to 18 GHz
87405C
Exceptional gain (25 dB) and flatness (1.5 dB) combined with a probe-power bias connection which eliminates the need for an additional DC power supply, makes these preamplifiers the ideal choice for spectrum analyzer or stand alone applications.
-
product
Multi Channel Analyzer
BOSON
Baltic Scientific Instruments, Ltd
Spectrometric device BOSON acquires and displays spectra with overlapping by energy up to 1000 timesNo resolution deterioration at operation in the beginning of spectrum energy rangeStable operation with preamplifiers of TPR type with output voltage swing up to +/- 10 V and reset duration up to 250 usAutomated P/Z adjustmentImproved dead time correctionSoftware-based spectrum stabilizationSetting and control of all parameters using colour LCD display with touch screenComplete remote control of Boson via software on PCAuto BLRAnalogue time dependent shapingSpectrum stabilizationDead time correctionOperation with preamplifier TPR
-
product
Low Noise Amplifiers for Radio Amateurs
Our Low Noise Preamplifiers are remarkable for extremely low noise, excellent SWR, high efficiency and a high IP3. The Low Noise amplifiers are especially selective and absolute stable therefore oscillation is avoided. Even if you have a bad SWR. This is the reason why radio amateurs and club-stations all around the world trust in Kuhne electronic equipment. The products are perfect for use in contests, EME, MeteorScatter, Aurora and Tropo DX. Small mechanical measurements and technical innovations from the professional sector, e. g. milled aluminium cases, enable high temperature stability and tower mounting. Numerous contest victories, records and first contacts with a country were and are achieved with Kuhne products. Don't compromise and get technology from Kuhne electronic!
-
product
Perseus SDR HF Receiver
PERSEUS is a VLF-LF-HF receiver made by Microtelecom is based on a outstanding direct sampling digital architecture. It features a 14 bit 80 Ms/s analog-to-digital converter with an exceptional 76 dB SNR (BW = 40 MHz), an high-performance configurable FPGA digital down-converter with an up to 1 MS/s output sampling rate and a 480 MBit/s, high-speed USB 2.0 PC interface. Unlike in lower class direct sampling receivers, the PERSEUS RF analog front-end has been carefully designed for the most demanding users and includes a 0-30 dB, 10 dB steps attenuator, a low-loss 10 bands pass-band RF preselector filters bank, and an high dynamic preamplifier with a top-class input third-order Intercept Point of more than 30 dBm. The resulting third-order dynamic range is 103 dB for SSB signals (2.4 KHz BW) and 107 dB for CW signals (500 Hz BW).
-
product
USB Preamplifier, 10 MHz to 4 GHz
U7227A
The U7227A, 10 MHz to 4 GHz USB preamplifier is designed to bring reliable gain and low noise figure to measurement systems improving the overall system performance and reduce systematic errors; a total solution to the X-Series signal analyzers to perform noise figure measurements.
-
product
Instrumentation
Unholtz-Dickie designs and manufactures a variety of transducer signal conditioners, accelerometers, remote charge preamplifiers, vibration monitors & limiters, transducer testers, buffer amplifiers and other special purpose instrumentation accessories for vibration testing.
-
product
MCT IR Detector Module
The MCT (Mercury-Cadmium-Telluride) IR (infrared) Detector Module is a thermoelectrically cooled detector element and preamplifier package optimized for acquiring spectral data with the LaserTune Quantum Cascade Laser (QCL) source.
-
product
Universal Preamplifier 14
UP14
For Two Dimensional Magnetic Recording (TDMR) and Heat-assisted Magnetic Recording (HAMR) Headamplifiers. Universal Preamplifier 14 (UP14) is designed for TDMR and HAMR Head Amplifiers. With new Guzik RWA4000 TDMR, UP14 allows to process signals from three Read Channels. It also supports two high speed data channels for Write data and Laser data. UP14 has two channels for dynamic TFC control and allows to program TFC power per sector and close loop TFC power control in each channel. UP14 can generate two programmable modulation signals for write data and laser data with bandwidth up to 20 MHz. UP14 consist of two boards. The first UP14 RW Board processes high-frequency signals: read-back signals, write data and laser data. The second UP14 Control Board provides power, control and low-frequency signal generation: TFC, write data modulation and laser modulation.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
Ancillaries - Radiated
EMC emissions can be at very low signal levels and pre-amplifiers can help to improve S/N ratio. The low level of emission signals can make them difficult to identify in noisy environments. RF filters are designed to attenuate the major sources of noise, thus making the task of measurement easier.