Filter Results By:
Products
Applications
Manufacturers
- TEAM SOLUTIONS, INC.
product
HandyScope HS6-DIFF With EMI & SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMEG-W5
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
product
Test Fixture, Shielding Effectiveness
EM-2108 | 1.5 GHz – 10 GHz
The EM-2108 is a standard test fixture for evaluation of the electromagnetic shielding effectiveness (SE) of planar materials. The fixture is a section of coaxial transmission line broken to allow the insertion of planar test materials. Although ASTM D4935-10 is currently limited to an upper frequency of 1.5 GHz, the EM-2108 meets and complies fully with both the impedance and SE requirements called out in ASTM test method D4935-10 up to 10 GHz. These results are shown in Figures 1 & 2. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred.
-
product
Digital Power Transducer
LP Series
*High accuracy 0.07% rd + 0.03% ro*Excellent long term stability*Outstanding over capability and temperature performance*Wide selection of input / output ranges*Meets ANSI C37.90 (1989) and BEAMA No. 219 tests*High magnetic field immunity*Real power - able to measure distorted waveform
-
product
Fluxmeter
DX-201
DX-201 digital fluxmeter is a precise magnetic measuring instrument, adopted low drift electronic integrator design and production. The most important features are test response quick, without data lose in the testing process. In the process of test samples flux by the Czochralski method, fast pull and slow pull datas are consistent, fine features especially shows in repeated measurements and regression testing. It can measure magnetic flux or magnetic moment matched with different fixtures according to users’ requirements.
-
product
High Performance Analog & Mixed Signal Test Solutions
Applicos
Effective mixed-signal test solutions demand know-how and experience. Low level analog signals need to be stimulated and analyzed near fast switching digital logic. Cross talk, magnetic fields, clock jitter, ground noise and non-linearity of components, are just a few of the problems that must be addressed. Applicos knows what it takes to design and produce high quality mixed-signal test solutions. They have been servicing the mixed-signal test industry since 1993 and have established a distinguished reputation for providing our customers with high performance, cost effective solutions. In 2018 we acquired Applicos B.V. to extend our portfolio for the ATE business.
-
product
Soft Magnetic Tester
Model SMT-700
KJS Associates/Magnetic Instrumentation offers the Model SMT-700 computer-automated magnetic test station for measuring the DC and AC magnetization curves, coercive field strength, and core-loss characteristics of magnetically soft materials, including: Si-Fe, Fe-Co, Fe, stainless steel, Ni-Fe alloys, soft ferrites and others. This modern line of laboratory instruments is designed specifically for accuracy, reliability, and ease-of-use.
-
product
Highly Sensitive Magnetization Switching Evaluation system
FMSS
The necessity of evaluation for media by thin film and high speed magnetic recording increases as high density of magnetic recording media. This equipment is newly-developed one which applies any time-range and pulse magnetic field to test sample, and detect magnetization after applied with highly sensitive resonating sample magnetometer.
-
product
Magnetic Effects Test
This test determines if an object can operate normally in strong externally generated magnetic environments. The magnetic effect test helps to assist in determining the proper location of the equipment in the installation.
-
product
Surge Tester
Qingdao AIP Intelligent Instruments Co., Ltd
Surge tester able to test various coils, motor, stator winding, relay/contactor coil, electric magnetic valve coil etc. and can be applied for maintenance, production line, lab and QC etc. Extension: single surge test or multiple tests options.Large storage: up to 1000 test groups can be established.Automatic determine: manual or auto test mode options and test results would be determined automatically.Support both touch screen and numeric keyboard operating.Data analysis: data can be exported in CSV format by USB flash drive.Surge determine items: area, area difference, corona, and phase.100MHz sampling frequency.3KV and 5KV voltage options.Voltage closed loop feedback ensures test precision.User permission management.Support MES connection (manufacturing execution system).
-
product
Portable Thickness Gauge
Magna-Mike 8600
The Magna-Mike® 8600 is a portable thickness gauge that uses a simple magnetic method to make reliable and repeatable measurements on nonferrous materials. Operation of the Magna-Mike is very simple. Measurements are made when its magnetic probe is held or scanned on one side of the test material and a small target ball (or disk or wire) is placed on the opposite side or dropped inside a container.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Measurements & Material Testing
MAGNET-PHYSIK Dr. Steingroever GmbH
, we can offer measurement tests and material tests of all kinds on hard and soft magnetic materials. It is also possible to carry out measurements on site. We carry out stray field measurements on your magnetization station in production in accordance with the professional association regulations (BGV). We also carry out magnetic field measurements on air freight goods in accordance with IATA 953.
-
product
Vibrating Sample Magnetometer
VSM
The VSM (also named M-H CURVE Hysteresis Graph TEST SYSTEM ) can be used for the measurement of the basic magnetic properties of the magnetic materials. Such as the Hysteresis loops of the materials, Magnetization curve, Warming Curve , Warming /Cooling curve, Cooling curve and the changes of the temperature as time goes away , then we will get some Magnetic parameters such as the Saturated strength of the magnetization, the left strength of the magnetization , Coercive force, the Max of Magnetic energy product,the Curie temperature and the Magnetic conductivity(the Initial Magnetic conductivity is included ). It can also measure the magnetic materials such as the powder, the particles, the films, the liquid and the massive.
-
product
Core Loss Testers
S30 and S30S Series
Stacks built with punched laminations can have a lot of quality issues. Even though the lamination material is tested in sheet format before any process, that alone is not sufficient to guarantee good quality stators. Wear and tear of the punch, bad welding, bad insulating coating in annealing add to the magnetic losses in the stator. It is always advisable to test the stator core in it's final format before winding to ensure good quality throughout the production batch.
-
product
Transformer Turns Ratio Testers
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
The Lightest Micro-ohmmeter In The Industry
RMO-H
The RMO-H is a portable, battery-operated micro-ohmmeter based on state-of-the-art technology, using the most advanced battery mode and switching technique available today. The high-capacity Li-Po battery allows the generation of a ripple-free DC current of up to 300 A. The test current is user-selectable and generated in an automatically regulated test ramp. During the test, the RMO-H increases the current before the measurement and decreases it afterwards. This significantly reduces magnetic transients.
-
product
Railway and Traffic Engineering Solutions
In the past, LXinstruments has already implemented a number of application-specific system solutions which cater for these special requirements. These solutions are often used to replace systems which have been in production for many decades. Our systems are not only employed for testing signal box technology modules, but also for testing train control system which are installed in the track bed. Due to the strong magnetic fields which occur at the DUT in combination with high voltages, the test systems require specific technical safeguards.
-
product
Dual Display HVAC Clamp Meter w/ Temperature
DL389B
UEi Test & Measurement Instruments
• Dual Display• Input jack locks• Worklight• Backlit display• Auto/manual ranging• Min/Max• Test lead storage• Magnetic mount• User temperature calibration• Auto power off• Degree ºF or ºC• Low battery indicator• Test lead holder on clamp• 2-Year limited warranty
-
product
Data Retrival and Analyzer Unit
MS 1200
*Retrieves the Data from Magnetic / Solid State Recorders (Supports JAGUAR, AN32, IJT, ALH Platforms)*RS232/RS422/Bi-Phase/USB interface with PC AT*Presents Error Messages and Test Reports*Replay, Analysis and printout of selected parameters*Calibration facility for ADR and DAU*Portable System for Snag Analysis of Aircraft*Reports in Tabular/Graphical formats*Used to check serviceability of ADR, DAU without removing from aircraft
-
product
Gaussmeter
DX-105
DX-105 Gaussmeter is a desktop gaussmeter. Which is based on the latest progress of the Hall Effect magnetic field measuring instrument.Adapt the high stability constant current source circuit technology to design and manufacture. Test probe adapts imported GaAs linear Hall-chip, the difference between any two probes is small, which can be replaced directly when it is damaged. DX-105 Gaussmeter is an ideal DC magnetic field test instrument.
-
product
Passive Magnetic Antennas, TX-Loop Antennas
A passive loop antenna which is matched to a resonance frequency of 13.56 MHz with 370 kHz bandwidth (-3dB)The purpose of the antenna is to produce defined magnetic fields at 13.56 MHz efficiently, i.e. to test near field communication devices (NFC) or RFID equipment.
-
product
Turns Ratio Testers
TRT Advanced Series
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
product
Magnetic Particle Liquid Checker
S-2A / S-2B
Magnetic particle liquid checker S-2 series is a test bar which can directly check the quality of magnetic particle liquid immediately. Magnetic particle liquid checker S-2A type has a sensor at the head of straight test bar.
-
product
Gaussmeter
DX-103
DX-103 Gaussmeter is a desktop gaussmeter.Which is based on he latest progress of the the Hall Effect magnetic field measuring instrument.Adapt the high stability constant current source circuit technology to design and manufacture. Test probes adapt imported GaAs linear Hall-chip, the difference between probes is small, which can be replaced directly when it is damaged, and is an ideal AC & DC magnetic field test instrument.
-
product
IGNITION COIL TESTER - ORANGE
MD76500M
*Non-intrusive, quick check tool instantly verifies active or inactive coil operation*Detects the magnetic field created by a coil energizing*Tool can be used to test coil on plug, coil near plug and coil pack systems
-
product
HandyScope HS6-DIFF With EMI, SureConnect & SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMEGS-W
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEGS EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
product
Magnetic-Field Test System
MTS-800
The MTS-800 is a compact test system for broadband generation and measurement of magnetic fields. Its internal components allow automatic EMC tests according to automotivestandards where high field strength need to be generatedor measured.
-
product
Digital Arrester Clamp Tester
ALCL-40
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
product
Electrical Measurements Test
The tests are performed to measure and collect data from electrical and electronic parts using various measurement methods including, but not limited, to the following: capacitance, resistance, winding resistance, insulation resistance, magnetic permeability, power input, and quality factor Q.
-
product
Magnetic Material Test Fixture
16454A
The 16454A is designed for accurate permeability measurements of toroidal-shaped magnetic materials. Since the construction of this fixture creates one turn around the toroid (with no magnetic flux leakage), the need of winding a wire around the toroid is unnecessary. Complex permeability is calculated from the inductance with and without the toroid. When the E4991A/4291B with option 002 is used as the measurement instrument, direct readouts of complex permeability are possible. In addition, it is furnished with a small and a large fixture to adapt to a wide range of sizes.