- Pickering Interfaces Inc.
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
product
Wire Harness Tester
Panther4HT Master- Slave DSU
Qmax Test Technologies Pvt. Ltd.
The Master- Slave DSU based Panther4HT Wire Harness tester is designed for testing and verifying electrical connections in a cable, harness, backplane or any other wired assembly. It offers unique Qmax MASTER - Slave concept and SATELLITE UNIT Options to avoid looping back of cable to the ATE. All Satellite Units communicates the measurements through LAN interface which is very useful for on-board applications in Aircrafts / Ships and similar applications where large cable looms are used. This i...show more -
product
Main Effects
The Analog Multi FX is an Authentic Analog Multi Effects Pedal equipped with everything you need to get the job done on stage and in the studio. It’s got a Switchless Optical Wah, Distortion, Effects Loop, Stereo Chorus, and Echo. Even better these are reissues of classic Morley circuits leading all the back to the 1970’s. And speaking of the 70’s it also has a new finish that pays homage to the original chrome Morley pedals. It’s Heavy-Duty spun stainless steel that’s Built like a Tank and looks great under stage lights. Each one is hand spun at our Illinois facility.
-
product
Loop A Line
TX916
The Loop a Line has been a Telstra standard for 20 years. It is probably the simplest time saving device available for contractors and technicians. Once fitted to the far end of a line you can switch between Open, Short, Connect, 600 ohm, and Tone modes allowing all installation and fault location to be performed from the one end without having to go back and forward from one end of the line to the other.
-
product
Mezzanine System
5041
ECM P/N 5041 provides eight channels of RS485 / RS422 I/O with fixed 120 ohm termination for each channel. Speeds are up to 30M bits per second. All channels power up as inputs. Also transceiver inputs are always enabled for loop back diagnostic use when the outputs are enabled. Software can enable outputs on a channel by channel basis.
-
product
IndustryPack system trouble shooter
IP-DEBUG-IO II
IndustryPack system trouble shooter providing testpoints on all of the IP IO signals. Loop back is as easy as wire-wrap. Custom feedback signals are supported with socket and power connector support. Now with 2 ribbon cable connectors to support in system debugging.
-
product
Rain Test Chamber - Twin Shower
The Drive-In Rain Test Chamber is generally used to conduct whole body testing of assembled vehicles under different rain test procedures to study and estimate their structural degradations and destructions induced by rain/water. The twin shower area with 1.1 million litre & 0.35 million litre volume is enclosed in a shed where arrays of pipes are interconnected to form zones to ensure the uniform spraying as per JSS 55555 test standard. The water gushes through the nozzle at a flow rate of ...show more -
product
Transponder Panel with GNS/GTN Interface
TA-330XP
This transponder panel is layed out to accommodate thecurrent Mode S panel mount units. The transponder caninterface with a GNS or GTN series radio for a morecomplete test of the transponder functions. The panelalso includes altitude, suppression, loop back and thestandard ARINC 429/RS232 interfaces as well. The panelcomes with both a digital voltmeter and ammeter.
-
product
Precision Current Loop Calibrator With Hart Communications
LC-110H
The Martel LC-110 and LC-110H are mA (loop) calibrators designed to take the loop calibrator class to the next level. The new LC-110 series feature a user friendly interface with dedicated buttons and a rotary encoder (Quick-Set Knob). This combination drastically reduces the time it takes to measure, simulate, or source both voltage and current and power up a loop. The rugged ABS plastic case is contoured to easily fit a technician's hand and the large back lit graphics LCD is best in class. Th...show more -
product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
product
Telemetry Simulators & Test Transmitters
Command Data Telemetry Simulators offer a dynamic way to create or change a PCM data stream on a word by word basis on the fly. This PCM data stream can be used to modulate an FM or SOQPSK RF output at S-Band or L-Band. In addition to simulating a new telemetry stream, the telemetry simulators can play back and loop an archived data file (which can also be changed on the fly) or create pseudo-random patterns.
-
product
Loop Antenna
ZHX7-0.009-200-1486
Loop Antenna, Frequency 0.009~200MHz, Linear Polarization, N-Female
-
product
Automotive Back Probe Pins
142-5
Flexible 1.5 inch silicon pins provide easy back probing connections for DMM and Scope measurements
-
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
8 Connector-Hole Back Extension
9401-BE
Semi-enclosed version of the cabling "doghouse" for the Hawk/PC chassis with rear panel punched to accommodate 8 50/37 pin d-sub connectors. Space is provided to mount the standard DG-style 100 pin edge connector paddles.
-
product
Loop Meters
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation ind...show more -
product
Line Loop Tester
8455
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
product
Antenna, Active Loop
EM-6876 | 9 KHz – 30 MHz
The Electro-Metrics EM-6876 Active Loop Antenna is used with EMI Receivers and Spectrum Analyzers with 50 ohm input and covers the frequency range of 9 kHz to 30 MHz.
-
product
mA Loop Calibrators
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
product
Peel Back Force Tester
PBFT
Precisely measure the peel back force of carrier tape to verify your packaging systems are within specification. Results can be printed and stored with the outgoing product.
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
THREE WAY BACK PRESSURE KIT
TU24APB
*Allows quicker and more accurate testing of exhaust blockages in catalytic converters, mufflers, etc*2-1/2" gauge features two multi-colored bands - idle and 2,500 RPM - with pressures shown in PSI and bar*Includes 6' of hose, enough length to test from driver's seat
-
product
Back Entry Style Temperature Gauges
Back Entry Style Bi-Metal Stainless Steel Temperature Gauges, 100mm face. Available in a selection of Temperature Ranges, with or without a 1/2" BSP Pocket
-
product
Open Loop Current Sensor
C03 50A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in systems for industry and commerce as well as in communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Loop Antennas
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
product
Three Loop Antenna
VVLA-30M
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
product
Loop Meter
MZC-310S
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
product
Single Loop Controller
1400+
The 1400+ controller is an evolved product from the West N4100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
product
Active Dual Loop Antenna
KH30936
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
product
Radiating Loops
The magnetic, handheld coil was designed to generate defined mag-netic fieldstrength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields.