Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Surge Voltage Generator
SSG 500
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
product
Ground Earth Resistance Tester
2678X
Shenzhen Chuangxin Instruments Co., Ltd.
Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.
-
product
Current Protection Relay
The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-20MH
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Convenient +5V single polarity power supply
-
product
Multifunction Tester
EASYTEST
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
20Hz Injection Kit Monitoring System
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
product
Earth Fault Indicator
The Sensorform Range of Earth Fault Indicators detects earth faults & short circuit faults on underground cables. A number of options are available for enclosure type, power source, indicator type, reset method, trip-level selection, and remote indication.
-
product
Cable Indicators
CableTroll
They are installed on Ring Main Units in distribution substations. They are used to detect short circuit and earth faults, and can be installed on most types of cable terminations. Some units will give separate indications for short circuit and earth faults, locally by flashing diodes and remotely through separate relay contacts or additional ComTroll communications modules.
-
product
DC Earth Fault Locator
GFL-T + GFL-R
The DC Earth Fault locator is suitable to test the DC Battery System and Trace Ground Faults. The system is suitable for Power Plants, Sub-Stations upto 765KV and other industries. The system is highly capable in tracing and pin pointing the DC earth faults in a live system without requiring any shut downs. The receiver sensitivity of 1mA and better is capable to trace most complex fault.
-
product
Multi-purpose Tester
DEL-101
Standard Electric Works Co., Ltd
● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.
-
product
Battery Boxes Testing Equipment
Battery boxes can be tested for faults by placing the box on a metal plate. By applying a test voltage to an electrode inside the box, the moulding can be checked thoroughly - particularly at the injection points - and any faults found. Defects will be identified by a spark passing from the electrode, through the defect itself, to earth (the conductive material placed outside the battery box.
-
product
Earthing Resistance Tester
JYD-10A
transformer neutral grounding resistor is the vital need in medium voltage AC distribution network that are also called by different names like Neutral Earthling Resistors. They are taken into use to limit the current that would flow through the neutral point of a transformer or generator in the event of an earth fault. They are also used for resistance grounding of connected generators and transformers.
-
product
Detector of Earth Faults on Multi/Single-Core Terminations
CableTroll 2310
CableTroll 2310 is an indicator for detection of earth faults (PtG) on multi-core and single core cable terminations. The unit uses NorTroll type current sensor (CT)
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
Line Indicators
LineTroll
Fault Passage Indicators to locate short circuit and earth faults.
-
product
Multifunction Installation Tester
COMBI519
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
RCD Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD triggers. The tripping time is also measured. These two parameters, tripping current and tripping time, are the safety-relevant parameters of an RCD. The various selectable test currents and characteristics that can be set with this device make the PeakTech 2710 the ideal companion for every electrician.
-
product
High Impedance Busbar Differential Relay
MIB
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
product
Multifunction Instrument
COMBI521EV
COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Digital LOOP/PSC/EARTH Tester
1824 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.
-
product
Current Clamps and Sensors
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
product
Ground Fault Locator
K-3837
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
Earth Fault Detector
K-3838
Kongter Test & Measurement Co., Limited
Kongter’s K-3838 earth fault detector is the updated model which is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the reliability of your electrical equipments. Our unique technique makes it safe and fast to handle earth fault in DC systems that are working online.
-
product
Relay Test Set
Cambridge Instruments & Engineering Co.
“CIE” Relay Test Set is ideal for Testing Protective relay, over current relay, earth fault relay by secondary injection method with help of digital timer.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-60NK
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
product
Medical Leakage Current Tester
2675Y
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.
-
product
20Hz Generator
Signals & Systems India Private Limited
In order to implement a 100 % stator earth fault protection based on subharmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the Band Pass Filter SBPF-1001 in the Stator Earth fault protection. The injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.
-
product
Loop Impedance Tester
CZ20054
Australian and New Zealand standards mandate testing of fault loop impedance on circuits not protected by RCD's, both at installation and after maintenance. The CZ20054 Loop Impedance Tester conducts earth fault loop impedance and prospective short circuit current (PSC) tests. The Aegis Loop Impedance Tester takes the confusion out of loop/psc testing by providing an automatic wiring check upon connection and single button operation.