Filter Results By:
Products
Applications
Manufacturers
- Virginia Panel Corporation
product
Receiver, ICon EMI , With Protective Cover And Strain Relief
310123102
Includes all of the standard features of the iCon, in addition to Electro-Magnetic Interference (EMI) protection. An earth ground terminal is included on the and a "mate first, break last" feature connects the earth ground circuit. The earth ground terminal on the strain relief prevents user shock and injury.
-
product
Phase Domain Induced Polarization/Resistivity Instruments
ULTRA MiniRes
*Light weight yet durable*Low power consumption*Lowest cost in the industry*Exploration to greater than 1000 feet**2.5 HertzMEASURES:*Earth resistivity*Induced polarization
-
product
Solar Array Simulator
G5.SAS
The G5.SAS series are unidirectional sources. It was developed specifically for testing inverters and simulating solar arrays and is suitable for use in laboratories and on test benches. The modular and finely graded G5.SAS series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3. The power supplies feature especially low capacitance values in the output filter stage and switchable earth leakage resistors for adaptation to the insulation measurement of the DUT.
-
product
Miller 400D
44550
No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)
-
product
Surge Voltage Generator
SSG 500
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
product
Gravimeter
Gravimeters are specialized accelerometers used to measure local gravity or variations in the gravitational field of the Earth. High-performance gravimeters and gravity gradiometers are well-suited for applications such as geophysical and geodetic surveying, precision navigation, exploration for natural resources, and underground fluid monitoring. Such sensors may also be useful for identifying special nuclear materials, treaty verification, and void detection.
-
product
NI-9477, 60 V, 32-Channel (Sinking Output), 8 µs C Series Digital Module
780174-01
60 V, 32-Channel (Sinking Output), 8 µs C Series Digital Module - The NI‑9477 works with industrial logic levels and signals to connect directly to a wide array of industrial relays, solenoids, and motors. Each channel is compatible with signals from 5 V to 60 V and … features isolation from channel‑to‑earth ground. You can wire the NI‑9477 channels in parallel to sink up to 20 A of current per module (1 A per channel maximum).
-
product
NI-9265, 4-Channel C Series Current Output Module
779334-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Charge Coupled Device (CCD) Image Sensors for Space and Ground-Based Astronomy
(CCDs) for Space science, Ground-based Astronomy, and Earth observation applications with an impressive record of successful deliveries to a wide range of customers over 40 years.All Teledyne e2v devices can be supplied partially or fully customised to fit the application and achieve the best possible system performance. CCD image sensor design, manufacture, test and characterisation are carried out in-house enabling control from start to finish. Multi-polysilicon, multi-metal and back-illumination options are available for high resolution, high sensitivity and very low noise.
-
product
Ground Earth Resistance Tester
2678X
Shenzhen Chuangxin Instruments Co., Ltd.
Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.
-
product
Socket Outlet Tester
Using the new Testavit Schuki 1 LCD and 3 LCD, specialists easily check to see if sockets, cable drums or connecting cables are correctly connected in 230 V installations. Due to three LEDs, the connection status can be quickly and clearly determined. In addition, through the finger contact, it can be tested to see whether an impermissible, high contact voltage is applied at the protective earth connection. In addition, using the Testavit Schuki 1 LCD, a 30 mA FI circuit breaker (RCD) can be triggered via a pushbutton.
-
product
Current Protection Relay
The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.
-
product
Inmarsat-C Physical Layer Tester
CPLT
Square Peg Communications Inc.
Square Peg Communications Inc.’s Inmarsat-C Physical Layer Tester (CPLT) is a software application that runs on the generic high-rate Physical Layer Tester (PLTH) platform. The CPLT supports testing of the physical layer performance and protocol implementations of Inmarsat-C Mobile Earth Stations (MESs) and Land Earth Stations (LESs).
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-20MH
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Convenient +5V single polarity power supply
-
product
NI-9265, 4-Channel C Series Current Output Module
783733-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Earth Contact Resistance Tester
SCR ELEKTRONIKS have developed an equipment namely Earth Contact Resistance Tester to test the appliance. To ensure the safety of operator it is essential that the Earth path (connection) should offer minimum impedance to by pass short circuit Current to Earth. This is ensured by measuring Resistance of the Earth path by passing heavy Current say 25 A. The Earth Contact Resistance Tester essentially comprises of a Variable Current source with digital Ammeter to measure the Current supplied. The Voltage drop across the Earth path is measured with a digital Voltmeter. Optionally for a particular Current (25 A) the meter can be calibrated in terms of Resistance. A timer is provided to switch off the Current after the Set Time.
-
product
Multifunction Tester
EASYTEST
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
High Voltage Tester For Hair Dryer & Hair Straightner
Every electrical apparatus or machine consists of two distinct sections - one which carries the electricity, and other which is isolated (insulated) from the electric currents. The former may be called the `Live' side whiles the latter `Earth’ side. A person near about the apparatus or handling it can safely touch the Earth side, but not the live side, for obvious reasons. To ensure that the isolation of the two sections is effected properly, the apparatus is tested by subjecting it to a Voltage much higher than the normal working Voltage. If the insulation is good, it stands the test without breakdown otherwise high electrical stress punctures the insulation at its weakest spot foretelling a later calamity to unwary user. Government Department- when buying electrical equipments- and all reputable manufacturers test every piece of equipment by this test called HIGH VOLTAGE TEST. It weeds out poorly insulate apparatus.
-
product
Barometers
These barometers can be found in the section to measure absolute pressure, differential pressure in respect to the atmosphere and negative pressure. There are barometers such as the DB2 digital barometers that have an internal memory for up to 750 Barometers to measure absolute pressure, differential pressure in respect to the atmosphere and negative pressure. readings and an analogue output of 0 to 1 volts. These barometers are perfect to measure atmospheric pressure, also called barometric pressure, is an expression for the weight of air (atmosphere) due to the earth''s gravitational pull. This pressure at sea level is 1013.25 mbars (milibars).
-
product
NI-9478, 50 V, 16-Channel (Sinking Output), 50 µs C Series Digital Module
779940-01
50 V, 16-Channel (Sinking Output), 50 µs C Series Digital Module - The NI‑9478 works with industrial logic levels and signals to connect directly to a wide array of industrial relays, solenoids, and motors. The NI‑9478 features programmable current limits, which provide customizable system protection that is ideal for solenoid and valve control applications. Each channel is compatible with signals from 5 V to 50 V and features isolation from channel‑to‑earth ground.
-
product
Partial Discharge Detection Calibration Device
Hangzhou Xihu Electronic Institute
Calibration Device of Transient Earth Voltage PD detector, calibration device of ultrasonic PD detector, calibration device of high frequency PD detector, calibration device of ultra high frequency PD detector.
-
product
Digital RCD Tester
8012 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Extra large LCD(78 × 67mm).● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Auto power off.● Auto off and off override.● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.●Frequency measurement indication.
-
product
Earth Resistance Tester
2678
Shenzhen Chuangxin Instruments Co., Ltd.
RK2678 series Earth Resistance Tester is used to measure the grounding resistance of the electrical equipments’ internal. It’s suitable for measuring the ground wire resistance of the various motors, electrical appliances, instruments and meters, household appliances and other equipment enclosure etc.
-
product
Upconverters
This high performance 2:1 redundant up converter system intended for use in professional applications in S band such as satellite earth stations. BMCR12-U2 includes three BMCU32 type high performance up converters and a BUSR10 redundant switch & control unit.BMCR12-U2 system can be controlled Ethernet (remote control) via the redundant switch. The converters can communicate with BUSR10 via serial RS-232 lines.
-
product
Combination Measuring Devices According to DIN EN 61557-10 (VDE 0413-10) are permitted
PeakTech Prüf- und Messtechnik GmbH
This innovative combination measuring device for testing electrical installations according to official laws convinces with its technical performance data in the high-end area. All important safety tests such as FI, voltage, loop, low-resistance, earth resistance and insulation tests for e-checks and new installations can be carried out safely by the electrician via the large 3.5“ TFT color display. Of course, the device comes with an extensive range of accessories, such as all necessary test leads, adapters, rods and the required software CD for the PC. The device can be charged with a power adapter or via a car adapter. During the daily use, this high-quality device is protected against dust and all-round water jets by its protection class IP 65.
-
product
Low Current DC/AC Clamp Meter
SE-07
Max.error by earth magnetic:≤±30mA1/f noise level :0.5mADisplay:3 3/4 digits LCD display with 3999 countsJaw size: 5mm(Max)Range:400mA/4AResolution:0.1mABand wide up to 1KHzOver range indication:Display“0L" or“-0L”Auto range,Auto power off,Auto zero adjustReading Rate:2.5 readings/secAuto Calibration
-
product
Highly Collimated Solar Simulators
This solar simulator is based on a Fresnel lens to collimate the light beam from the arc lamp source to infinity, which results in highly collimated illumination of the target spot. A 2.5kW xenon ozone free lamp is used as the light source. The spectral distribution of the xenon light source, along with the use of specially calibrated AirMass filters, closely simulates the sun’s true spectral distribution in various conditions on Earth.
-
product
C Series Voltage Output Module
The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Digital LOOP/PSC Tester
8025 LP
Standard Electric Works Co., Ltd
● Battery is not used.● 3 ½ digit LCD (2000-count).● Backlight function.● 15mA loop measurement which will not trip ELCBs.● Convenient and easier for users to measure the loop impedance directly without bypassing the wires.● Wiring check function.● Over temperature protection.● Over voltage protection.● Built-in voltmeter.● Built-in earth tester.● Built-in loop/psc tester.● Safety standard : EN 61010-1 CAT III 300V EN 61326-1
-
product
Contact Resistance Meter
CRM 200B+
CRM directly measures micro-ohm values at 200A DC under live EHV switchyard conditions quickly & accurately. It is specially designed to reliably measure micro-ohm contact resistances of Circuit Breakers, Isolators, Busbar joints, earth switch joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards up-to 765 kV. SCOPE’s ability to make electronics work in such environment enables CRM to measure mili-volts signal in the presence of kilo-volts noise.
-
product
Earth Ground Testers