Filter Results By:
Products
Applications
Manufacturers
Atmospheric
of or related to elements and conditions surrounding a planet.
See Also: Atmosphere, Meteorological, Haze
-
product
Open Path Combustible Gas Detector
SafEye (Quasar 900)
Teledyne Gas & Flame Detection
The Open Path Combustible system detects hydrocarbon gases by analyzing the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. This is accomplished between a pair of units: a Flash Source and a Detector that can monitor a distance of up to 200 meters.Open Path Combustible Gas Detectors are robustly designed and can handle the toughest environments: 316L stainless steel housings that meet IP66/IP68 and NEMA 250 6P egress standards; circuit boards epoxy coated for protection; MIL-C-810C testing for humidity, salt, fog, vibration, mechanical shock and temperature extremes; and SIL-2 approval per IEC61508 is a final statement in reliability.
-
product
Barometers
These barometers can be found in the section to measure absolute pressure, differential pressure in respect to the atmosphere and negative pressure. There are barometers such as the DB2 digital barometers that have an internal memory for up to 750 Barometers to measure absolute pressure, differential pressure in respect to the atmosphere and negative pressure. readings and an analogue output of 0 to 1 volts. These barometers are perfect to measure atmospheric pressure, also called barometric pressure, is an expression for the weight of air (atmosphere) due to the earth''s gravitational pull. This pressure at sea level is 1013.25 mbars (milibars).
-
product
GEOPHYSICS, SEISMIC, and ATMOSPHERICS RESEARCH RECEIVER
Type RAS-1
Called the RAS-1, the receiver is designed for ultra low and very low frequency scientific research work, including the exploration of low frequency emissions due to seismic and earth-quake activity, study of atmospheric phenomenon such as "whistlers", and low frequency Sudden Ionospheric Disturbance (SID) and electromagnetics phenomenon. The RAS-1 will receive signals from under 200 Hz. To over 250 KHz in both narrow bandwidth modes as well as broad badnwidth reception.
-
product
Digital Manometer
Shenzhen Graigar Technology Co.,Ltd.
A manometer is a pressure measuring instrument, or pressure gauge, often limited to measuring pressures near to atmospheric. Manometers come in two types Analog Manometers and Digital manometers. Analog Manometers. An analog manometer is a U-tube shaped glass tube partially filled with liquid.
-
product
On-board Emissions Measurement System
OBS-ONE GS Unit
OBS-ONE is the latest Portable Emissions Measurement System designed for engine/vehicle certification under real road conditions.It measures concentrations of emissions (CO, CO2, THC, NOx, NO2), particulate matter, air-to-fuel ratio, exhaust flow rate, GPS data, environmental conditions (atmospheric temperature, humidity and pressure) and calculates mass emissions.OBS-ONE features the highly adaptable, intelligent operating platform called “HORIBA ONE PLATFORM” which integrates other ONE series product data and optimizes test cell operation.
-
product
Transducer with RS232 Interface
RS232 transducers / transmitters for temperature, humidity, atmospheric pressure and CO2.
-
product
Gas Chromatography Equipment & Test
AMETEK MOCON offers a variety of gas chromatography (also known as GC) equipment and instruments that continuously monitor single or multiple gas components for a variety of applications and industries. AMETEK MOCON uses Baseline’s industrial-grade process gas chromatographs (Process GCs) to give particular information about the composition of a gas stream or sample encountered in an industrial or atmospheric application, including qualitative (species) and quantitative (quantity) information.
-
product
Flash Diffusivity Analyzers
DLF 2800
The Discovery Laser Flash DLF 2800 is an advanced freestanding instrument for the measurement of thermal diffusivity and specific heat capacity of materials from room temperature to 2800°C. The distinctive design incorporates a proprietary laser, laser optics, detector, and furnace technologies, and along with the unique six-position sample carousel, ensures unprecedented measurement accuracy and sample throughput. With the ability to operate in a variety of atmospheric conditions, including inert gas or under vacuum, the DLF 2800 can characterize a wide variety of materials, including polymers, ceramics, carbons, graphite, composites, glasses, metals, and alloys.
-
product
Upgrade For Star SAFIRE® 380-HD and 380-HDc
380X Upgrade
The Star SAFIRE® 380X is a hardware, firmware, and software upgrade to support advanced image aiding features for our globally renowned Star SAFIRE 380 gimbal systems, including Star SAFIRE 380-HD and 380-HDc. The new 380X skillet upgrade reduces operator workload for faster, smarter decision support and features customizable configurations for multi-tile video management and visual user interface, and touchscreen and streaming tablet support. It also features an integrated moving target indicator (MTI) and de-scintillation filter, that removes atmospheric effects to reveal clearer, sharper detail from greater distances.
-
product
Precision Barometric Transmitters
HD9408.3B… Series
HD9408.3B is a barometric transmitter that uses a piezoresistive high accuracy and temperature-compensated sensor. It allows to measure the atmospheric pressure in the range from 500…1200 hPa, providing extreme accuracy and time stability, with excellent repeatability, low hysteresis, and excellent temperature behavior.
-
product
Thermo-Hygro-Barometer
D4130
Thermometer, hygrometer, barometer is designed for measurement and datalogging of temperature, relative humidity and atmospheric pressure into the internal non-volatile memory.
-
product
Datalogger for IAQ Analysis
HD37AB1347
Datalogger for indoor air quality analysis (IAQ). Measurement of airspeed, temperature, relative humidity, atmospheric pressure, CO² and CO.
-
product
Pressure/ Vacuum Sensors
There are three different types of pressures that can be measured using Premier Electrosystems' Pressure Sensors: Gauge, Absolute, and Differential. Gauge pressure is the pressure measured relative to the ambient atmospheric pressure.A typical application for a gauge pressure sensor is to measure liquid levels in a vented tank using the difference in hydrostatic pressure and ambient atmospheric pressure. Absolute pressure sensors will give the result relative to zero (a perfect vacuum). This is useful in applications where there is a direct effect of altitude on the pressure being measured. Differential pressure sensors measure the difference in pressure between two points. Differential pressure sensors are often used to monitor airflow in HVAC applications.
-
product
Water & Weather Node
SmartGuard
The next generation sensor and instrument HUB for Ocean, Lake, Reservoir, Estuary and River Hydrometric stations.Monitoring water and weather conditions is essential in many operations and the SmartGuard node is well suited for stand-alone stations powered by battery and solar power utilizing wireless real-time data communication.Designed for ease of integration of new and existing sensor technologies into a single Aanderaa observatory node with modern self-describing XML data output formats.SmartGuard interfaces with all Aanderaa atmospheric and in water sensors, along with most 3rd party sensors.
-
product
SWIR Imagers
SWIR imagers (short wavelength infrared) are an important group of surveillance electro-optical imagers due several reasons. First, advances in InGaAs technology enabled design of relatively low cost SWIR imagers. Second, InGaAs imagers are very sensitive and can generate images of observed scenery even at dark nights. Third, SWIR imagers are less vulnerable to bad atmospheric conditions than TV/LLLTV cameras working in visible/near infrared band. Fourth, SWIR imagers can generate hi-res images even if they are built using much smaller optics than used for design of thermal imagers.
-
product
IK Level Tester
IK07-10
IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
product
Web Sensor
T7511-2
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Digital Meteorological Sensor
ZET 7123
Digital meteorological sensor ZET 7123 is a measuring unit with two in-built sensors, one of which is used for measuring relative humidity and temperature, and the other one – for atmospheric pressure measuring. ZET 7123 meteorological sensor measuring unit converts signal from the sensing elements to temperature, humidity, and pressure values. The obtained values are transmitted via CAN interface and displayed in the measurement units set by the user.
-
product
Combined Probe for IAQ
P37AB147
Temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide) combined probe, complete with SICRAM module.
-
product
Three-Parameter Water Quality Analyzer (three-parameter water level gauge)
HR8833
HighReach Measuring & Controlling System Co.,Ltd
The HR8833 integrated pressure water level gauge is a three-parameter (water level, water temperature, conductivity) measurement product. It can be used with digital atmospheric pressure meter. It can be externally powered and self-powered by internal battery. It can be The product includes a water level sensor, a temperature sensor and a conductivity sensor, a built-in large-capacity non-volatile memory and a high-capacity long-life lithium battery, For three-parameter hydrological parameter measurement of surface water, groundwater and marine environment.
-
product
Humidity And Temperature PROfilers
RPG's profiling radiometers are mainly used to derive vertical profiles of atmospheric temperature and humidity (RPG-HATPRO). The infrared radiometer extension allows to cloud base height and ice cloud detection.The radiometer series covers high-resolution temperature profiling of the boundary layer and low-humidity applications. All models of the series provide accurate total amounts of atmospheric water vapor and cloud liquid cloud. RPG radiometers are stand-alone systems for automated weather-station use under nearly all environmental conditions. A variety of retrieval algorithms (custom designed and global standard algorithms) can be selected.
-
product
Automation Equipment
Through its SMART and COMPACT automated equipments, RECIF Technologies proposes a complete offer for wafers/substrates atmospheric handling, and provide IC manufacturers with innovative and configurable solutions responding to wafers and frames handling requirements.
-
product
High Voltage Isolation Switch Contact Pressure Tester
WA1401
Wuhan Sangao Electrical Test Installations Limit Co.
Isolation switch is the high voltage switch equipment, it was large and frequently use in power system . The outdoor isolating switch is the only completely exposed in the atmospheric environment electrical equipment, It is also a electrical equipment affected by climatic conditions influence the most direct and most serious. The operating conditions is relatively poor, It is easy to generate fault of mechanical or electrical. Especially the finger contact part is easy to be affected by rain, dust and harmful gas invasion, resulting in poor contact caused fever, provide the spring with contact pressure due to heating and annealing for reducing the pressure, so that more cause finger heat form vicious spiral eventually burn out finger accident. In maintenance often only pay attention to replace the obvious failure and fracture of spring, but spring to reduce the pressure can not judge and replacement, so again in the operation, each finger current distribution by the pressure difference, The greater the difference between the current distribution is not uniform, long-term operation will occur is bad and the overheating. Fever finger will be vicious spiral, a finger contact bad will spread over the entire bad contact. At the same time, there are a lot of isolating switch contact pressure can be adjusted, if in maintenance adjustment pressure is not enough or each finger to adjust the pressure difference will also appear afore-mentioned phenomena.
-
product
SparkFun Atmospheric Sensor Breakout
BME280
The SparkFun BME280 Atmospheric Sensor Breakout is the easy way to measure barometric pressure, humidity, and temperature readings all without taking up too much space. Basically, anything you need to know about atmospheric conditions you can find out from this tiny breakout. The BME280 Breakout has been design to be used in indoor/outdoor navigation, weather forecasting, home automation, and even personal health and wellness monitoring.
-
product
Air Amplifiers
Nex Flow® Air amplifiers are compact, low cost air flow “movers” that are virtually maintenance free. Applications include the venting of fumes and smoke, conveying of low weight materials, and entraining a high volume of air to cool, blow off, and dry. Air Amplfiiers use the “Coanda effect” to draw in the surrounding atmosphereic air while consuming only aminimal amount of compressed air. These products can amplify airflow up to 17 times (depending on the size) resulting in dramatcally reduced levels of noise. Air Amplifiers (also called Air Movers) draw in atmospheric air from the back of the unit as well as having downstream entrainment further amplifying the flow. They are used for cooling and venting. While the force produced for blow off decreases as the amplifier outlet diameter increases, these Air Movers are ideal for cooling because of the high velocity outlet fow and and are much more effective for cooling compaed to air nozzles.
-
product
Web Sensor
T7511-4
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Spring Impact Hammer IK Level Tester
IK01-06
The most of luminaires manufactory were request to do IK level test (Impact Protection), LISUN can supply the IK test instrument. IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
product
Web Sensor with PoE
T7611
PoE Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.
-
product
Atmospheric Pressure Gas Analyzers
The Cirrus™ single-quadrupole mass spectrometers are powerful analytical tools for a wide range of laboratory and industry-based gas analysis applications. The Cirrus family, featuring the Cirrus™ 3 and Cirrus™ 3-XD atmospheric pressure gas monitoring systems are ideal for analysis of bulk gas, gas composition, and detection of trace gasses and contamination. These powerful, versatile and customizable platforms, when combined with Process Eye™ Professional software and its recipe-based control, can significantly boost your productivity.
-
product
Digital Meteorological Sensor
ZET 7023
The ZET 7023 weather sensor is a measuring unit with two in-built sensors one of which is responsible for measuring relative humidity and temperature, and the other one, for atmospheric pressure measuring.