Contactless Laser Extensometers
Jinan Testing Equipment IE Corporation
Model LE-05 and LE-15 extensometers measure strain optically, without contacting the specimen, using laser diode technology. The extensometers are self-contained and portable. They may be interfaced with a variety of testing machines and data acquisition systems using the ±10V analog output or bi-directional RS-232 serial port. Operation may be local or remote. A digital display is included. The scanning beam is always perpendicular to the specimen, unlike most laser extensometers. This eliminates errors when viewing through windows in chambers. It also minimizes sensitivity to the distance between the extensometer and the sample. Because the unit measures reflected light, no receiver is required behind the sample.
-
product
High Temperature, Low Strain, Extended Performance Capacitive Extensometers
Model 7650A
Jinan Testing Equipment IE Corporation
Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200℃ (2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.
-
product
Long-Travel Extensometer For Soft Materials
DSES-1000
A Long-Travel Extensometer That Is Now Easier to Use and Even More Precise The DSES-1000 is a long-travel contact-type extensometer able to measure displacement up to the breakpoint in tensile tests of rubber and other soft materials. The upper and lower arms are clamped to respective gauge positions using a simple single operation, with each arm tracking sample elongation independently.
-
product
Contactless Video Extensometers
Jinan Testing Equipment IE Corporation
Deformation measurement of samples during material testing with use of the Video extensometer MercuryRT allows applying multiple virtual probes (Movement Sensors)on markers and advanced image featuresto be tracked, including the natural pattern of the sample surfaces.The common resolution of standard system is within 500 nm and 5 m. The system fulfils class 0.5 or B-1 of classification according to ISO 9513 and ASTM E83. In certain camera use case, the system resolution reaches the level of 100 nm - 500 nm and system fulfils the class 0.2. The strain resolution can reach 10 microstrains. Material testing,Component testing ,FEA validation,Vibrography .
-
product
Contacting Extensometers
AMETEK Sensors, Test & Calibration
The contacting extensometers are designed for accurate strain and extension measurement of a material up to a maximum sample thickness of 25 mm.
-
product
High-Temperature Extensometers < 600 °C Capacitive
Instron® High-Temperature Extensometers are perfect for testing advanced composites, metals, polymers and other materials at elevated temperatures. This series incorporates a capacitive sensor that does not require any cooling. The extensometers come standard with a sensor conditioner unit providing a 0-10 V output with exceptionally low noise. These extensometers can be attached to round and flat specimens to perform tensile, compression, and cyclic tests.
-
product
Economical Hydraulic Manual Universal Testing Machine
WEW-D Series
Jinan Testing Equipment IE Corporation
WEW-D series hydraulic manual UTM is suitable for testing tension, compression and other strengths of various metallic or nonmetallic materials with high strength. The hydraulic manual UTM is capable of testing the characters of materials on physical & technology properties. As a manual control & economical UTM, the hydraulic manual UTM is with reasonable and reliable configurations (load cell or pressure transducer, extensometer, photoelectric encoder, servo motor & driver, standard screws), which can satisfy ordinary testing requirements. Digital controller and computer with software can be equipped on this machine to realize the test date/curve collecting and process. The hydraulic UTM of economical type is easy to operate and is versatile in the applications of metallurgy manufacturers such as steel mills & alloy, reinforced bar etc.
-
product
High Temperature Furnace COD Gages (1200 C or 1600 C)
Model 3548COD
Jinan Testing Equipment IE Corporation
These COD gages mount on a water-cooled bracket, which is mounted on the furnace side cut-out or with optional load frame support brackets. The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. Mounting brackets may be integrated with the furnace cut-out. Epsilon can also provide optional load frame mounting brackets to fit your test frame. Contact edges on the test sample should be somewhat rounded (not sharp knife edges) for best performance with this model. The Model 3548COD extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Diametral Extensometers for Rock and Concrete Testing
Model 3975
Jinan Testing Equipment IE Corporation
Designed for accurate measurement of small diametral strains such as those required to determine Poisson’s ratio of rock, concrete and asphalt samples. The units are designed to be used in conjunction with the Model 3542RA axial averaging extensometer.
-
product
High Temperature Un-Cooled Extensometers (700 C)
Model 7642
Jinan Testing Equipment IE Corporation
These extensometers use a high-temperature capacitive sensor and do not require any cooling. They will operate up to the maximum temperature limit of most environmental chambers used in materials testing. The Model 7642 is ideal for testing composites, metals and high temperature polymers in tensile, compression or cyclic testing. All units can be displaced in both compression and tension. The extensometer is supplied with the advanced DT6229 controller. The standard output is 0-10VDC analog signal, factory calibrated with the extensometer. This system provides a number of functional enhancements, including high speed digital output, built in calibration and tare functions, analog and digital filters, and more.
-
product
Miniature Transverse (Diametral) Extensometers
Model 3475
Jinan Testing Equipment IE Corporation
A miniature extensometer designed for general purpose transverse or diametral strain measurements on small or thin specimens. May be used simultaneously with the Model 3442 miniature axial extensometers or the Model 3542 axial extensometers.
-
product
Averaging Axial Extensometers for Large Compression Samples
Model 3542RA
Jinan Testing Equipment IE Corporation
Designed primarily for compressive strength tests on rock, concrete and other large compression samples, this model measures axial strain on opposite sides of the test specimen, and the output is an average of the two readings. Gauge lengths from 1 to 8 inches (25 to 200 mm) and measuring ranges from 0.050 to 0.250 inches (1.2 to 6 mm) are available.
-
product
Video Extensometers
AMETEK Sensors, Test & Calibration
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
product
Long Travel Extensionmeters
The Instron model XL (long travel) extensometer is a precise device for measuring strain in highly extensible materials such as elastomers, semi-rigid plastics and films. Designed for use with electromechanical testing instruments, Instron XL units can be used to measure specimens elongation's up to 10 in or 250 mm. An optional of 15 in or 375 mm travel is also available.
-
product
Extensometers for Simple Performance Testing of Asphalt
Model 3909
Jinan Testing Equipment IE Corporation
Designed for measuring axial displacements in the simple performance tests prescribed by NCHRP Report 465, and determining dynamic modulus of hot mix asphalt per AASHTO TP062.
-
product
Extensometers
Extension measurement is one of the areas that complements our range of UTM program. The result is a comprehensive range of high class variations. The product selection is arranged as follows:*Non-contact extensometers with and without measurement marks.*Contact extensometers: Sensor arm extensometers, incremental and analogue clip-on extensometers as well as extensometers for compression and flexure tests.
-
product
High Elongation Extensometers
Model 3800
Jinan Testing Equipment IE Corporation
The main body of this unique extensometer remains stationary during testing, held in position by the adjustable magnetic base included. Only the very light, small traveling heads move as the sample elongates during a test. These attach to the sample with small spring clips. Each head pulls a cord out from the extensometer as the head moves. These models use high precision, low friction potentiometers, and, as a result, have a wide range of factory selectable outputs. The extensometer is driven by an excitation voltage and has output proportional to the input. They can be provided with high level outputs (approximately 2-8 VDC) or ones that mimic strain gaged devices (2-4 mV/V). When set to mimic strain gaged extensometers, the Model 3800 can be used with virtually any signal conditioning electronics designed for strain gaged sensors. The potentiometers employ a hybrid wire wound around conductive plastic, which provides excellent long term stability. The output from the extensometer is readily interfaced with most existing test controllers, and may be directly input to data acquisition systems and chart recorders. Please let us know at the time of order what type of output and connector you require.
-
product
SSG Series Strain Gauge Extensometers
Shimadzu’s SSG series of strain gauge extensometers are compliant with ISO, JIS, and ASTM tensile test standards, including those for plastics and metallic materials These lightweight, precision extensometers feature a wide elongation measurement range, while retaining the flexibility to measure using small gauge lengths, and support both rod and flat plate shaped specimens. Consisting of an elongation sensor and amplifier, this extensometer is suitable for use with metals and hard plastic materials, and is fastened securely to specimens with screws. Calibration using an extensometer calibrator allows the extensometer to meet JIS and ISO Class 0.5 and ASTM Class C standards for higher accuracy.
-
product
Extensometers for Creep Compliance and Tensile Strength Testing of Asphalt
Model 39
Jinan Testing Equipment IE Corporation
Designed to many of the needs for testing asphalt core samples in 4 and 6 i ch diameters. The unit meets test method requirements for strain measurement developed under the U.S. Federal Highways SHRP program.
-
product
High Temperature Axial Torsional Extensometers (1200 C or 1600 C)
Model 7650
Jinan Testing Equipment IE Corporation
Model 7650 extensometers are primarily used on round specimens tested in bi-axial test machines capable of simultaneous axial and torsional loading. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to minimize crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.
-
product
High Temperature Self-Supporting Furnace Extensometers (1200 C)
Model 3448
Jinan Testing Equipment IE Corporation
Epsilon developed this unique high temperature extensometer for testing metals, ceramics, and composites at the high temperatures produced by furnaces and induction heating systems. A combination of features make these extensometers easier to use and better in performance than other similar high temperature extensometers.The units are held on the specimen by light, flexible ceramic fiber cords. These make the extensometer self-supporting on the specimen. No furnace mounting brackets are required. The side load on the test sample is greatly reduced because of the self-supporting design and light weight of the sensor. Most materials testing furnaces with a side cut-out for an extensometer will readily accept a Model 3448. For induction heating systems, a different ceramic cord placement allows the extensometer to easily pass between the coils.The combination of radiant heat shields and convection cooling fins allow this model to be used at specimen temperatures up to 1200℃ (2200°F) without any cooling. An optional tiny air fan does enhance stability at the highest temperatures and is recommended for the highest accuracy and for tests with small elongations. The fan comes with a magnetic base for support so it can be mounted at any convenient location near the extensometer. Fan cooling is not generally needed for induction heated systems. High purity alumina ceramic rods are used. These are available in lengths as required to fit your furnace. A spare set is included with every extensometer. Specify chisel, vee chisel or conical contact points as desired.Most units operate equally well in tension and compression. Thus tensile, compression and cyclic tests like low cycle fatigue can all be performed with a single unit.For vacuum furnaces, special models are available. Epsilon can also provide a radiant heat transfer cooled version. This requires that the extensometer module be surrounded by a water cooled enclosure with a front slot for the ceramic rods.
-
product
Bolt Extensometers for Proof Load Testing
Model 3565
Jinan Testing Equipment IE Corporation
The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
High Temperature, Low Strain Capacitive Extensometers (1200 C or 1600 C)
Model 3648
Jinan Testing Equipment IE Corporation
These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. They mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The overall design reduces any influence from common lab environment vibrations.The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. These units are made to order in many different gauge lengths and measuring ranges.The extensometer comes with a signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically. They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.
-
product
Auto Calibration for Load & Extensiometer
Jinan Testing Equipment IE Corporation
TE electronic calibration module provides an easy way to calibrate load cell or extensometer and signal conditioning electronics without using a mechanical calibrator. It enables performing on-site electrical calibration and easy to periodically “spot check”, which will help ensure that the load cell and the extensometer and electronics are calibrated correctly.
-
product
Axial Extensometer
Model 3542
Jinan Testing Equipment IE Corporation
These extensometers are designed for testing a wide range of materials, including metals, plastics, composites and ceramics. All will work in both tension and compression. The dual flexure design makes them very rugged and insensitive to vibrations, which permits higher frequency operation.They come standard with Epsilon’s quick attach kit, making it possible to mount the extensometer on the test specimen quickly and easily with one hand. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The Model 3542 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.For gauge lengths 100 mm (4 inches) or greater see Model 3542L.
-
product
Semi-automatic tensile testing machine
The controller of this testing machine automatically applies an appropriate load and puts the extensometer between the gauge lines, etc. after the sample is set. It provides measurement with high repeatability.
-
product
Environmental Chambers
The Instron range of 3119-600 Series environmental chambers provides extensive temperature testing capabilities for evaluating material properties under non-ambient testing conditions. A full range of complementary grips, pullrods and extensometers is available.
-
product
Contacting Extensometers
The contacting extensometers are designed for accurate strain and extension measurement of a material up to a maximum sample thickness of 25 mm.
-
product
One-Touch, Strain Gauge Extensometers
SSG-H Series
The SSG-H series of strain gauge extensometers are compliant with ISO, JIS, and ASTM tensile test standards for hard plastics and metal materials Featuring a wide elongation measurement range with the ability to measure using small gauge lengths, these lightweight, clip-on strain gauge extensometers attach to both rod and flat plate specimens.
-
product
Miniature Averaging Axial Extensometers
Model 3442RA1
Jinan Testing Equipment IE Corporation
With gauge lengths of 1 and 2 inches (25 and 50 mm) and measuring ranges of 0.050 and 0.100 inches (1.2 and 2.5 mm), the Model 3442RA1 was designed for applications where tensile or compressive strength tests on small rock, concrete and other small compression samples is desired.