Filter Results By:
Products
Applications
Manufacturers
- CAMI Research Inc.
product
4-Wire Resistance Measurement | Continuity & HiPot Cable & Wire Harness Testers
An add-on option for the CableEye HVX high voltage cable tester series that permits expanded testing for contact and wire resistance as low as 1 mΩ. After checking for opens, shorts, miswires, and resistance limits, the 4-wire Kelvin measurement applies a user-selectable test current from 10 mA to 1 A to determine connection resistance within 1 mΩ. The resistance profile of a model cable may be stored and used as a basis of comparison during later testing to reveal cold solder joints, faulty crimps, recessed pins, pin contact contamination, improper wire gauge, and stress-extruded wire.This option may be purchased with any new HVX tester, or added as an upgrade to any of your existing HVX testers.
-
product
Antenna Mast
AM-400
The AM-400 antenna mast is suitable for making EMC radiated emissions measurements in an open area test site or test chambers.
-
product
OTA Power Measurement Solution
NRPM
The R&S®NRPM is a fully calibrated and individual scalable OTA power measurement solution for benchtop application or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz it is perfect for Over-the-Air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of the transmit antenna output power.
-
product
Shield Level / Pathloss Equipment
SG1000B/PR1000A
The SG1000 Signal Generator and PR1000A Preamplifier have been designed to simplify the measurement of shielding integrity in a shielded enclosure. When coupled with a high stability spectrum analyzer and an appropriate selection of test antennas, the SG1000/PR1000A combination can measure shielding effectiveness at all of the NSA 94-106 (supersedes NSA 65-6) defined test frequencies from 1 kHz to 10 GHz.The PR1000A amplifies the received signal from the test antenna and overcomes the high noise figure of the companion test receiver or spectrum analyzer. The PR1000A will ensure that the system noise figure will be less than 4.5 dB at all test frequencies from 1 kHz to 10 GHz. When used with a spectrum analyzer measurement bandwidth of 100 Hz, the system exhibits a sensitivity of -150 dBm at the test antenna output.To overcome high cable loss between the test antenna and the PR1000A assembly at 10 GHz, a remote low noise pre-amplifier (Praxsym PN 310-010091-001) is mounted directly onto the 10 GHz antenna.
-
product
FieldFox Handheld Microwave Analyzer
N9913A
4 GHz max frequency Carry the world's most integrated handheld RF analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without warm-up Calibrate simply with QuickCal Lightest all-in-one analyzer at only6.6 lb. (3.0 kg) Industry-leading 3 year warranty Every spec verified, adjustments included Lock in support & peak performance from the start
-
product
Antennas
At MVG, we design our antennas with outstanding performance in mind. It begins with a careful design process, alternating simulation and measurements. It extends to the use of the most advanced machining techniques and quality materials to achieve tight mechanical tolerances. That's why all our antenna characteristics are outstanding. And that's why we can guarantee the best electrical performance/operational bandwidth trade-off. No competitor matches this level of excellence.
-
product
Power Quality Analyzer
PQM-703
Power quality analyzer PQM- 703 is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x . In relation to the PQM -702 has new functions like recording of transients with max. sampling frequency 10 MHz (rapid changes in voltage) and control signals. Minimal transient capturing time is 650 ns. It is intended for a very wide range of users who need to control the quality of power with a mobile device , which fulfills the requirements of a multi-sheet standard IEC 61000 for class A analyzers. This applies to measurement accuracy, measurement methods, and synchronization of time with a standard signal. The last condition is met with a built-in GPS module with an internal antenna. If the analyzer is installed inside, it is possible to use an additional antenna with a 10m-long wire. If the antenna is situated outside, GPS signal will be attainable without any problems and used for the synchronization of an internal clock.
-
product
GPS-Aided Inertial Navigation Systems
INS
The INS was unveiled in 2001 when Inertial Labs started manufacturing its first MEMS-based, IP67 and IP68 sealed and OEM versions, MIL-STD-810G qualified multiple interfaces and COM ports Single and Dual Antenna GPS-Aided Inertial Navigation Systems (INS). Each INS contains an Inertial Labs developed Tactical or Industrial-grade Inertial Measurement Units (IMU) and reliable single or dual GNSS receivers from suppliers like NovAtel, u-blox and Septentrio.
-
product
High Dynamic Receivers
ZRX
converter series with high dynamic range receivers. Typical applications are antenna measurements (OTA) and signal analysis. The ZRX Receivers are used wherever full S-parameters are not required.
-
product
Antennas
Aaronia AG specializes in the development and construction of quality antennas of all types. With the antennas developed and manufactured in Germany, almost all measurement scenarios can thus be served. This includes, for example, measurements in the field, EMC measurements in the laboratory, but also very special and unique solutions such as IsoLOG® 3D tracking antennas, which are also used for the AARTOS drone detection system developed by Aaronia. Here, Aaronia AG guarantees the highest quality at reasonable conditions.
-
product
Measuring Small Antennas
If you have a small PCB with a small antenna you can't use a thick cable and a large connector. Not only is this impractical (how to connect the connector?) but the metal bulk will also affect the antenna and grounding properties of your PCB. The measurement will be useless. MegiQ promotes the use of the small and popular UFL connector and its associated cables. The UFL socket fits on almost any PCB and it can be improvised on a board without a UFL footprint.
-
product
Near-field Chambers
Most antenna measurements need to be carried out in the far field; that is, the test antenna should be illuminated by a plane wave. Typically this is carried out by providing sufficient separation between the source and the AUT so the spherical wave approaches a plane-wave character.
-
product
Antenna, Dual Ridge Horn
EM-6963 | 18 GHz – 40 GHz
Model EM-6963 can be individually calibrated for use in EMI/EMC compliance measurements as well as for general purpose measurement antennas over its specified frequency range.
-
product
Antenna Measurement Frequency Extenders
AET/AER
Farran’s AET and AER frequency extenders are a dedicated Test & Measurement solution for antenna performance verification.
-
product
Monopole Antennas
Our Monopole Antennas provide superior performance in electric field measurements. The Active Monopole Antenna can drive any receiver with 50W input impedance and will perform FCC, MIL-STD and TEMPEST tests. The passive rod is used for transmitting, to perform shielding effectiveness and immunity testing.
-
product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
product
Antenna Analyzer
Measuring antenna SWR ratio with graphic display in a selected frequency range.Measuring antenna Impedance ( Z = R + j X )Measuring antenna resistance RMeasuring antenna reactance X, all the above with graphic display in a selected frequency range.Quick search for antenna resonance frequencyVery suitable for antenna measurement and adjustment.Portable and small size.Easy and intuitive operation
-
product
Power Monitoring Kit For SAR System Validation
PMK
Test labs have a daily requirement to ensure SAR measurements are highly accurate. SAR systems must be vigorously checked to ensure the measuring accuracy meets the system manufacturer uncertainty budget. The PMK features technologies usually found in more expensive equipment at an affordable price. The ability to measure the S11 parameter for dipoles and antennas while continuously monitoring their linear behaviour differentiates the PMK from other systems. The ART-Fi PMK is an all-in-one solution that requires only three connections to perform automatic, highly precise validations and verifications. The lack of moving parts also leads to improved durability and fewer bugs, faults, and workarounds.
-
product
Omni-Directional Antenna
EM-6104-1 | 20 MHz-18 GHz
The EM-6104-1 is an omni-directional, dual band, hybrid antenna covering 20 MHz-18 GHz. The antenna features wide frequency coverage making it an excellent choice for a variety of applications such as general purpose measurements as well as wideband security applications. This lightweight antenna is ideal for deployable applications that require wideband coverage in a very small footprint. The antenna’s elements collapse for convenient storage and transport. The antenna is configured to mount on a standard ¼-20 tripod stud. The EM-6104-1 Omni-Directional antenna is supplied with an EM-6089 Battery Pack.
-
product
Frequency Shaped Isotropic Electric Probes
PI-SH-FCC, PI-SH-ICNIRP
An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.
-
product
Passive Intermodulation Analyzers
The current standard of PIM testing offers a well-known system of two primary carriers and a calculated PIM frequency, which is monitored via a spectrum analyzer. This provides a measurement of the overall linearity of the antenna system and the surrounding environment.
-
product
Comb Generator
RefRad X
A comb generator is built inside a conical antenna element. Therefore no cable between antenna and generator is required. Thus leads to repeatable measurement results and reliable simulation of radiation performance.Optionally a fibre link for synchronisation with the receiver is used.Frequency Range 10 kHz - 3 GHzFrequency Spacing 10 kHz, 1 MHz, 5 MHz
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
product
RF Shielded Enclosure for Pre-Compliance EMC and CTIA Testing
QuietBox-AR "Mini-Range"
The Raymond RF QuietBox-AR is a mobile solution for pre-compliance EMC and CTIA testing, 3D antenna pattern measurement, and total radiated power & total isotropic sensitivity testing. Fully equipped with client-specified broadband absorber, integrated antenna and rolling cart, the QuietBox-AR is a cost effective option for product verification prior to fully compliant testing.
-
product
EMF Measurements Antennas
An isotropic antenna that allows to carry out radiated emission and environment exposure measurement (elettrosmog) to the radio frequencies in proximity of radio and television stations and repeaters for mobile telephone.
-
product
Antenna Test & Measurement Solutions
MVG offers the broadest choice of solutions based on near-field, far-field and compact range measurement techniques for Antenna, EMC, RCS and Radome testing. Our solutions support the measurement needs of the Aerospace & Defense, Telecommunications and Automotive industries, as well as Academic and Research institutes. MVG standard systems are customizable, facilitating selection, allowing for specifications, and guaranteeing an upgrade path for the enhancement of system capabilities. From components and parts to full turn-key solutions, the right combination enables our customers to meet specific measurement needs in a variety of testing configurations.
-
product
RF Proximity Detector
Type RPD-2 AND Type RPD-2A
The Type RPD-2 Radio Frequency (RF) Proximity Detector is designed to detect and locate devices that radiate radio waves in the high frequency to low microwave frequency range. Such devices often include surveillance and “spy” equipment. The Type RPD-2, when used with the different sensors, will detect the emanation of the radio wave within a confined area, and then isolate its location to within approximately a square foot. The type RPD-2A may be used as an RF field strength indicator for antenna field strength measurements. The RPD-2A is identical in function except that the meter scale is calibrated in relative dB units.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
Measurement
Site VSWR
The Site VSWR measurement is done according to CISPR 16-1-4 in the frequency range from 1 GHz to 18 GHz using broadband omni directional antennas in horizontal and vertical polarisation. The volumetric test method is applied (test volume needs to be specified), test distance 3 m - any other distance upon request. The ground plane has to be covered with absorbing material.
-
product
Handheld Vector Network
ZNH
R&S®ZNH is a full two-port handheld vector network analyzer that offers one-port cable and antenna measurement and full two-port S-parameter measurements. The touch based interface is simple to operate and a configuration overview menu makes measurement preparation more efficient. The R&S®ZNH may have a small form factor but it is complete in every detail and delivers high performance and all the key functionalities.
-
product
FieldFox Handheld Microwave Vector Network Analyzer
N9926A
14 GHz max frequency Carry the world's most integrated handheld T/R VNA analyzer Expand your measurement flexibility with optional 2-port VNA, time-domain, vector voltmeter, cable and antenna analyzer and more Save time by simultaneously measuring all four S-parameters with a single connection Perform accurate testing with QuickCal, full 2-port unknown thru Cal, TRL Easily measure average and pulse power with a USB power sensor