Filter Results By:
Products
Applications
Manufacturers
Thermal Test
Designed to produce a temperature change in a device. The magnitude and rate of this change should induce a sufficient thermal stress fatigue to identify sources of potential failure without causing catastrophic failure of all components. (sigmasystems.com)
See Also: Thermal, Thermal Shock
- Pickering Interfaces Inc.
product
LXI EMR Low Thermal EMF Matrix 14x33
60-511-004
This high density 1-pole matrix has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix.
-
product
2 Zone Thermal Shock Test Chamber
2-Zone Thermal Shock Testing Equipment with programmable electronics.
-
product
Caibration Equipment For Lab Use
In the field of high-power semiconductor testing, PONOVO has launched a smart test platform with high-speed high-frequency, high-voltage, high-current power sources, combined with high-speed, high-precision high-voltage, high-current analog acquisition technology and high-speed digital processing control system. The platform can complete the testing of dynamic parameter parameters, static parameters, thermal parameters and mechanical parameters, and power life parameter of various types of high-power semiconductor devices, modules, and chips, which could meet different testing requirements. It is the universal testing platform for automated testing for different application purpose, such as the research and development testing, engineering acceptance test, factory acceptance test, etc.
-
product
High Temperature, Low Strain, Extended Performance Capacitive Extensometers
Model 7650A
Jinan Testing Equipment IE Corporation
Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200℃ (2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.
-
product
Thermal Test Vehicles
TTV
Thermal Engineering Associates, Inc.
Using the TTC-1002 Thermal Test Chip as a basis, TEA offers TTVs in flip-chip, bare die, BGA packages for a variety of thermal simulation, reliability, qualification, heat sink characterization, and TIM characterization activities. Selective unused balls are sequentially connected together for daisy-chain applications.
-
product
Circuit Breaker Analyzer
CAT Standard Series
The CAT Standard series circuit breaker analyzers & timers are stand-alone or a PC-controlled digital instruments for circuit breakers condition assessments. The timing channels record closing and opening of the arcing, resistor, and auxiliary contacts. CAT Standard series records graphs of both, trip and close coil currents and displacements of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the pre-insertion resistors (if present in the circuit breaker). Test results can be downloaded to a USB memory stick or saved to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Test results can also be printed on the 80 mm (3.15 inch) thermal printer (optional accessory) in tabular and graphical form. CAT Standard series provides an easy selection of different operational modes:
-
product
Mechanical Load Tester
Solar modules and collectors, whether on roofs, in façades, or freestanding, are often exposed to high mechanical stress or load: A deep layer of snow or strong winds can greatly affect the materials and connections. Mechanical load test stands accurately test the durability of PV modules and thermal solar collectors.
-
product
Thermal Platforms
Thermal Platforms are perfect for using conductive transfer to test components hot and cold, they work best for parts with a low or flat physical profile. They transfer heat outstandingly for programmed or very rapid heating and cooling transition times (that’s why they’re called hot plates or cold plates as well), and have a precise temperature control every time from cryogenic temperatures to extremely hot
-
product
3U VPX RL Thermal Load Simulation Module
The 3U power test module is an ideal solution for evaluating heat dissipation in a rugged conduction cooled VPX cage or chassis. This card is a thermal load in the chassis to evaluate the heat dissipation. The chassis can be monitored with temp sensing probes and or FLIR imaging. Different wattages are selected by setting dip switches. The +5 and 3.3V loads are on the top of the module. The +12V and -12V loads are on the bottom side of the module.
-
product
Primary Current Injection Testers
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
product
Boiler Tube Oxide Scale Nondestructive Tester
DX-201'
This instrument is suitable for measuring non-magnetic stainless steel pipe inner layer accumulation rust. It can use a rechargeable battery, without power supply when test, which is suitable for outdoor environment operation. It can be used 4 hours once charge saturation. This product has been used by Hunan Xiangtan Power Generation Company Limited, Wuhan University, Nanyang Henan Yahekou Power Generation Co., Ltd., Anhui Huainan Pingwei power plants and Changsha thermal power plant, received good evaluations.
-
product
Franklin Tester
Model FT1
The Franklin tester FT‐1 is designed to measure the surface insulation resistivity of electrical steel sheet according to the ASTM Standard A717 and IS:649. This test method is suitable for quality control in the application of insulation coating. For ease of testing FT‐1 automatically set 300 PSI pressure on the sample by the inbuilt hydraulic unit and it is capable to set the desired test temperature of the platform. Then the regulated supply of 0.5V gets on and the current flowing through the insulation get measured. The calculated insulation resistivity will be displayed on graphics LCD display and as well as on printed report via thermal printer.
-
product
PXI 32 Channel I/O, High and Low Side Driver
40-413-003
The 40-413 range is available in three configurations, a high side only, a low side only and a combined high and low side (shown here) –each capable of driving 2A loads. Each output is fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments.
-
product
Milliohm Meter
16502
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
product
Explosion Proof UV Inspection Light
he Labino MB Hercules Ex is an extremely durable product specifically developed for use in areas where the risk of an explosion is high. Offshore Oil Rigs, Refineries, Aerospace, and Defense often require explosion proof products to ensure safety for their inspection teams. The Midbeam Hercules Ex has successfully completed extremely tough tests, including tests for thermal conditioning, Impact Tests, Drop Tests and IP tests that led to the ATEX certification (Certificate: ITS17ATEX402144X). This unique product is suitable for use in extreme weather conditions varying from 104° Fahrenheit (+ 40° Celsius) to minus 4° Fahrenheit (- 20° Celsius).
-
product
Thermal Cycling and Humidity-Freeze Test
King Design Industrial Co., Ltd.
*10.4" TFT LCD, touch-type Chinese/English display controller.*Temperature/humidity setting procedure, LCD curve display device (set to “curve display”).*Chinese/English/LCD operation/troubleshoot/guiding window.*State-of-the-art intelligent auto-dispatch “heat load value” coolant servo valve flowrate algorithm control.
-
product
Thermitest
THW-L2
Designed with speed and operational simplicity in mind, the Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. In less than 2 seconds, a single measurement of small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. Using a non-stationary measurement approach, the THW-L2 uses rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a 60 mm heating wire that is fully inserted into an isothermal sample. A constant current source (q) is used to heat the sensor wire and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) is determined from the plot of temperature rise vs. logarithm of time and is used in the calculation of thermal conductivity (λ). Liquid samples of high thermal conductivity will have a lower slope, while liquid samples with low thermal conductivity will have a higher slope.
-
product
Automatic Test Equipment
Wewon Environmental Chambers Co, Ltd.
Automated Test Equipment (ATE) adopts PID+PWM principle VRF (Refrigerant flow control) technology to realize low temperature and energy saving operation (servo control technology of refrigerant flow based on thermal condition of electronic expansion valve). Realize the automatic constant temperature of the studio.https://www.wewontech.com/automatic-test-equipment/
-
product
Thermal Shock Chamber
The Thermal Shock Chamber is specially designedwith independant temperature zones to facilitatethe automatic transfer of product under testthereby simulating a temperature shock to test the reliability of the product as per military and other international standards.
-
product
Standard And Custom Targets
Santa Barbara Infrared manufactures a wide range of targets for visible, and infrared/FLIR electro-optical testing. These targets complement our complete line of Visible and IR test products. Our targets are designed to function with one of SBIR’s target wheels. Utilizing a variety of manufacturing techniques, including conventional machining, photochemical etching, electro-deposition, electrical discharge machining (EDM) and laser cutting. SBIR targets are manufactured to exacting mechanical tolerances. SBIR manufactures all of the targets specified by MIL-STD-1859 and the Tri-Service Guide for thermal imager testing.
-
product
Hybrid Single Site Test Handler
3110
Chroma Hybrid Single Site Test Handler 3110 is a full range ATC (Active Thermal Control) test handler capable of handling device bodies up to 120x120mm with 450kg force load.
-
product
Climate Control Test Chamber
ACMAS's Climate Test Chamber is ideally suited for specimen test requiring quick changes of temperature. It covers various applications from JEDEC and IEC test standards. ACMAS Thermal Cyclic Chamber is equipped with advanced technology such as specimen temperature control which allows linear specimen temperature rates of change during rapid thermal cycling or accurate temperature ramp control. This chamber is also known as Climatic Test Chamber and Climate Controlled Test Chamber.
-
product
Battery Test Equipment
Shenzhen Bonad Instrument Co., Ltd.
The tests that can be performed by lithium-ion battery safety testing equipment include temperature cycling test, thermal abuse test, high altitude low-pressure simulation test, vibration test, shock test, external short-circuit test, forced internal short-circuit test, drop test, crush test, impact test, nail penetration test, burning test, etc. These test items mainly apply to various lithium-ion cells such as 18650 cells and prismatic cells, lithium-ion batteries, lithium-ion battery modules, lithium-ion battery packs, and so on.BONAD battery safety testing equipment complies with various standards such as IEC 62133, IEC 62133, UL 2580, UN 38.3, UL 1642, etc. For more information, please contact us, BONAD will provide you with professional technical consultation and high-quality testing equipment.
-
product
TVAC CalPod, 20 GHz
85532B
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button, and without removing the DUT or re-connecting standards. Very useful in thermal-vacuum chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the testing to perform a normal re-calibration.
-
product
Chamber/Pyroelectric Task
Radiant's Chamber/Pyroelectric Task sets the sample to a series of temperatures by performingGPIB control of an external thermal device. At each temperature it captures the sample’s polarization response and/or small-signalcapacitance. These are combined to calculate the pyroelectric coefficient. The Pyroelectric Task is to be used with a Radiant Test System and a Linkam Stage (-196C to 600C), Thermal Chambers, Hot Chucks, or a Furnace to automatically measure the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled. Radiant's Pyroelectric measurement Task can be added to Vision at additional cost. This measurement suite fully characterizes the pyroelectric charge (polarization) response of the sample under test. The Pyroelectric Task suite controls various thermal controllers such as Quantum Design, Lake Shore, Delta Design, and many others. Detailed Listing of Thermal Controllers Registered in Vision. The Chamber/Pyroelectric Task is quoted upon request.
-
product
Climatic Testing
Environmental Test Chamber. Environment Associates' complete Climatic test facilities offer precise simulation of Temperature, Humidity, Altitude, Thermal Vacuum, Salt Fog, Sand and Dust, and Rain as well as many other specialized environments. Microprocessor Control along with calibrated recorded measurements and outstanding attention to detail by our technical staff make for a perfect test everytime.
-
product
Environmental Test Chamber
High and Low Temperature Test Chambers, ESS Environment Stress Screening, 2 Zone Thermal Shock Test Chamber, 3 Zone Thermal Shock Chambers, Walk-In Chambers, Burn-in Room and Aging Test Chambers, Altitude Chambers, Industrial Drying Oven, Salt Spray Test Chambers, Temperature Humidity Vibration Comprehensive Test Chamber, Test Machine Series, Custom Made Environmental Test Equipment, Double-Layer High and Low Temperature Chamber, Explosion Proof Temperature Chamber For Power Battery, etc.
-
product
DiodeTester
FECPLS500
Frothingham Electronics Corporation
The PLS500 automatic tester is designed primarily to do SURGE testing either as single pulses or with Forward and Reverse bias, according to methods 4066-1 or 4066-2. In addition, it can also test VF with rectangular pulses and THERMAL RESPONSE either in DVF (mV) or degrees per watt. All three test types may be performed in a single test program.
-
product
Measurement System For Testing & Binning Of Back-End LEDs
TP121-TH
The photometric specifications of LEDs must meet very high tolerance requirements regardless of whether they are to be used in general, automotive or other specialist lighting applications. This is often a problem since the manufacturing tolerances of LEDs can be higher than those permitted in the end-use applications. Also, LED binning by LED manufacturers in order to classify LEDs based on their tolerances is performed with flash mode testing using pulsed current flow. However, end-use applications of the LEDs often operate in constant current mode and with significant thermal effects. The sophisticated LED processing industry therefore requires measurement devices that can be used for both manufacturer-compliant pulsed mode, as well as constant current operation mode. When the LEDs are run in constant current mode, the junction temperature has significant influence on the performance and lifetime of the LED. Therefore, test systems should be able to test the LEDs at specific junction temperatures.
-
product
Thermal Test Enclosure, -90°C To +220 °C, ≥100 DB, 300 MHz - 18 GHz
dbSAFE TSE
Compatible with all platforms of temperature forcing units and thanks to the DVTEST “waveguide” technology; isolation performance will not be impacted. The temperature range of the units will be -90°C to +220°C.
-
product
Non-Destructive Testing
The essential feature of active thermography is the targeted supply of energy to the test object. A temporal and spatial characteristic heat flow results depending on the geometry and thermal properties of the test subjects. Its progression on the surface of the test object is captured by a thermographic camera.