- Pickering Interfaces Inc.
product
PXI/PXIe Battery Simulator Module, 4-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
43-752A-912
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Primary Current Injection Testers
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
product
Transforming Analog Circuit Breaker Testers
MAC-21
The MAC-21 uses proven microprocessor and A/D converter technology to provide real-time waveform analysis. This ensures accurate true-RMS readings of current pulses, even with DC offset and distortion, which are typical in primary injection testing. Intelligent threshold algorithms provide accurate trip time measurement. Integration of measurement and control functions allow advanced features such as preset on times, auto ranging, and optional printer or computer interface.
-
product
Primary Test Equipment
LET-400-RD
It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.
-
product
Primary Current Injection Test Trolley
SCR ELEKTRONIKS have developed primary and secondary Current injection test trolley for Switchgear manufacturers for testing of ACB , MCB , MCCB. It is low Voltage high Current source with control circuitry, digital read out for test current and trip time measurement. We can select different links of CT range as per the required test Current.
-
product
Single Phase Secondary Injection Test Set
T200A
T200A Single Phase Relay Testing Kit is the best universal secondary injection test set for engineers who need to do all single phase relay test and other basic primary testing which may require single phase long-term high current injection.
-
product
Primary Current Injection Kits
During installation,testing,especially if the protective gear is connected to the power line via a current transformer it is advisable to use our Primary Injection Test Set. Keeping this in mind a wide range of Primary Current Injection Test Sets are being manufactured by "NMC”.
-
product
TD Series High Voltage DC Test Set
TD2000A
TD series testing equipment is a High Voltage DC Test Set consisting of control unit and DC high current output unit. And the TD series HVDC primary injection system includes 3 types, which could output 2000Adc/4000Adc/ 8000Adc and 0.1% high accuracy, suitable to be used for different HVDC testing requirements, such as in HVDC Converting station, or railway transportation line, etc.
-
product
Current Injection
K&S Engineering and Scientific Ltd
The outputs are continuously variable from zero and are all isolated. The current outputs can be used at twice their continuous rated current on a 25% duty cycle with a maximum ON time of 5 minutes.
-
product
Primary Current Injection Sets
Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Contact Resistance Meter
CRM 100C
CRM 100C directly measures resistance values with DC current injection under live switchyard conditions.The CRM 100C is specially designed to reliably measure contact resistance of Circuit Breakers, Isolators, Bus Bar joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards. It can also be used for testing cables, graphite bars etc.
-
product
EMC Testing Services
Our sophisticated technology can meet the diversified needs of customers. Component Tests: Immunity, Radiated Immunity, ALSE, TEM cell, Bulk Current Injection, Stripline, Conducted Immunity, Transient Immunity, Power Supply Variations, Electrostatic Discharge Emissions, Radiated Emissions, Conducted Emissions, Transient Emissions. Vehicle Tests - Radiated Immunity, Radiated Emissions.
-
product
TriRaptor Three-phase High Current Injection
The TriRaptor is the only really portable three-phase injector in the market providing stabilized current in the range of 3000 A and beyond. It has been designed with the same ergonomics and performance characteristics found in the popular Raptor system, so it is really easy to use and can be transported by a single person in a regular vehicle.
-
product
Mini Digital Multimeter
HH2103
Basic Accuracy 1.0%. LCD display 2000 count, 12.8mm figure height. Manual Ranging at your choice (19 Range). Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 2000KΩ. Diode test. Square Wave Signal Injection
-
product
Primary Current Injection Tester
SLQ
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
It's a high voltage generator insutrment for tesitng.
-
product
Manual Ranging Digital Multimeter
HH3502
Double Injection Casing. High Accuracy (basic accuracy 0.5%). 3-1/2 digit Jumbo LCD display 2000 count with symbolic signs and back light. Manual Ranging High Voltage test up to 1000V DC and 750V AC. Higher Current test up to 20A AC/DC. Transistor test. Diode and Continuity check. Measure Resistance up to 20MΩ
-
product
Protection System Tools
Megger’s comprehensive range of products for relay tests includes high current primary injection, relay phase angle, end to end line protection GPS timers and relay current amplifiers.
-
product
Primary Current Injection
PCI-600
The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers.
-
product
Primary Current Injection Test Set
T 3000
T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers
-
product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
product
Secondary Current Injection Test Trolley
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.
-
product
Electronic Primary Injection Test Set
eKAM
eKAM is the new fully automatic electronic primary injection test equipment. e KAM test system includes two portable units: one control unit with a large graphical display, that adjusts the output, and one current unit (up to 2000, 3000, 5000A). It can also perform Step and Touch tests and ground resistance tests.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Relay Test Equipment
Vanguard Instruments Company, Inc.
The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers. The PCI-600 is versatile and can also be used in many other applications that require a high-current source.
-
product
Primary Test Equipment
LET-4000-RDM
It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.
-
product
Primary Injection Test Equipment
High current injection units for primary testing of over current relays and circuit breakers.
-
product
High DC Primary Current Injection Test Set
PDC15k
PDC15k High DC Primary Current Injection Test Set adopts high-frequency invert principle to realize the high DC current output capability, with very small size and light weight. PDC15k is modular designed with changeable modules and multi-functions local control software.
-
product
Test Leads
AL-34WB
Standard Electric Works Co., Ltd
● Wire length: 1.2m approx. Silicone insulated wire (1000mm) with wire connected to straight input plugs (130mm PVC wire), and wire for clamp (100mm PVC wire). ● Outside diameter of silicone insulated wire: 5mm Outside diameter of PVC wire: 3.5mm● Input plug color: Red•Green•Black•Blue ● Current rating: 5A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031 CAT IV 300V
-
product
Primary Injection Test Systems
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
-
product
Primary Test Equipment
LET-400-RDC
The LET-400-RDC is designed to perform most of the primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.