Filter Results By:
Products
Applications
Manufacturers
Relay Drivers
Control the energized state of relays.
- Pickering Interfaces Inc.
product
PXI/PXIe Microwave Relay, Single SPDT, 2.5GHz, 75Ω, 1.6/5.6
40-780B-751
The 40-780B-751 (PXI) and 42-780B-751 (PXIe) are single SPDT 2.5GHz 75Ω unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
product
Microwave and RF Switching Systems and Drivers
CXM Series
This series is typically used for frequencies from DC to 40 GMHz. We use microwave relays, splitters, programmable attenuators and many other microwave components from the worlds most popular vendors to build standard or custom systems to your specifications. There are a large variety of 1x2 through 1x12 microwave relays available in Normally Open, Failsafe, Latching, Terminated or special configurations to suit your needs. Or simply buy the driver chassis and use it to control your own components. Since Cytec doesn"t build microwave components we can put the systems together with whatever parts you prefer and stand behind the warranty for you.
-
product
PXI Relay Driver Module
The PXI Relay Driver Module controls up to 64 external relays with up to 50 VDC or 600 mA per channel drive capacity when using an external power supply. Modules can drive small DC motors or other inductive relay coils, and they include overcurrent, overvoltage, and flyback protection to ensure long operation. The PXI Relay Driver Module allows you to build custom switch configurations while using the standard IVIcompliant NISWITCH driver software.
-
product
High Voltage DC Load ISSRs
Series SI
Series SI relays are designed to switch high voltage (high power) DC loads. These devices feature the latest generation of High Voltage IGBT Technology as well as an innovative isolated driver to ensure fast power turn on and OFF. The relays feature triggered control input to avoid linear control risks and fast switching times. The relays also offer an LED for status.Available options include:SI60DC100 100A, 0-500 Vdc Load; 4.5-32 Vdc Control
-
product
Ethernet To Parallel Digital Interface Boards
ICS's Ethernet Parallel Digital Interface boards provide the user with a wide range of IO signals that can be user configured to match virtually any application. These Ethernet boards are available with high power relay driver boards and with optional firmware designed to simplify switching applications. The 80x3 boards have high-power TTL signals that can sink 48 mA and source 24 mA. Pullup resistors make it easy to interface with CMOS logic and to sense contact closures. User configures data byte direction and polarity. The 80x3 boards are VXI-11 compliant for operation with NI or Agilent VISA, LabVIEW and VEE and support raw socket connections. The new 8113 board is a CMOS close of the 8013 board with user set 3.3 or 5 V logic levels. Pinouts and command set is the same as the 8013 board. The 8113 communicates with TCP/IP(Raw Socket) protocoland and also has a RS-232 Serrial Port. All boards are designed for mounting against the rear panel or inside a chassis and use our Ethernet Wiring Kit for easy connection to a Ethernet Connector on the rear panel.
-
product
Medium- to High-Power DC Load ISSRs
Part No. S60DC40
Series S60 relays switch medium- to high-power DC loads. These devices feature the latest-generation MOSFET technology as well as an innovative isolated driver to ensure fast power turn on and off. The relays feature triggered control input to avoid linear control risks and fast switching times. The relays also offer an LED for status.Available options include:S60DC40 40A, 0-350 Vdc Load; 4.5-32 Vdc Control
-
product
Medium- to High-Power DC Load ISSRs
Part No. S75DC150
Your product description goes here.Series S75 relays switch medium- to high-power DC loads. These devices feature the latest-generation MOSFET technology as well as an innovative isolated driver to ensure fast power turn on and off. The relays feature triggered control input to avoid linear control risks and fast switching times. The relays also offer an LED for status.Available options include:S75DC150 150A, 0-42 Vdc Load; 4.5-32 Vdc Control
-
product
GPIB Parallel Interface
Model 4803
* 4803 Board provides 40 high-power TTL I/O lines that can sink 48 mA or source 24 mA. * Easily interfaces to TTL or CMOS signals and contact closures. * User can configure the data bytes as inputs or outputs.* Transfer data as bits, bytes as data strings or transparently.* Dual GPIB headers support connections to a GPIB Connector/Address Switch Assembly or to a GPIB Flat Ribbon Cable Assembly.* Optional Relay Driver board drives 24-40 relays.
-
product
16-Ch SPST 10A-277VAC High Current
YAV90086
16 power relays SPST Switching up to 2770VA 16A Switching 125Vac 10A Switching 277Vac CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
DAQ Terminal Board
* Provides screw terminal connections for the Analog, Digital, Relay Driver and Thermocouple signals.* Mates with the 62-pin connector on the 2307 boards and the 2367 Minibox™.
-
product
Serial Parallel Interface
Model 2313
* Provides 128 high-power TTL I/O lines that can sink 48 mA or source 24 mA. * Easily interfaces to TTL or CMOS signals and contact closures. * User can configure the data bytes as inputs or outputs.* Transfer data as bits, bytes as data strings or transparently.* Separate headers for RS-232 and RS-485 signals. * Optional 2313 Flat Ribbon Cables mount DE-9 male or female connectors on the rear panel. * Optional Relay Driver boards with 64 or 128 Relay Drivers.
-
product
PXI/PXIe Relay Driver Module, 64-Channel, 5V Relay Supply
40-411A-001
The 40-411A-001 (PXI) and 42-411A-001 (PXIe) are 64-channel relay drivers and are part of a range of modules with 16, 32, 48 or 64 channels of low side current drive. To use the module, simply connect a positive voltage source to one side of the relay coil and the other side to an output channel. Each output is capable of sinking up to 1 A of continuous current.
-
product
PXI RF Multiplexer Switch Module
PXI RF Multiplexer Switch Modules are ideal for high-channel-count applications that need to connect measurement or signal generation instruments to various test points on devices or units under test(DUTs or UUTs). PXI RF Multiplexer Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor(FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a multiplexer that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NISwitch Executive provides additional software tools to help you design, build, and deploy your switching system.
-
product
Mainframe or -E Expansion Chassis - Control up to 16 Modules with up to 8 Relays per Module
LXA/128-MF
These Chassis control up to 16 modules with up to 8 relays per module. A large variety of different switch modules are available to build almost any configuration. Modules are available to build matrix or mux configurations or discrete relay modules. Input detection modules, output driver modules and proto board modules allow custom systems for almost any application. LEDs on the front panel show switch and power status. A thumbwheel manual control is optional.
-
product
PXI Flexible Microwave Module, Dual SP6T 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
40-890-005
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
Serial Parallel Interface
Model 2303
* 2303 Board provides 40 high-power TTL I/O lines that can sink 23 mA or source 24 mA. * Easily interfaces to TTL or CMOS signals and contact closures. * User can configure the data bytes as inputs or outputs.* Transfer data as bits, bytes as data strings or transparently.* Dual Serial headers support conections with baud rate switch inputs or to a Serial Flat Ribon Cable Assembly. * Optional Relay Driver board drives 24-40 relays. * 114732 Board has the DIN connector on circuit side for use with the X3DVR Relay Driver Board or for piggyback mounting.* All other specifications are the same as listed above for the 2303.
-
product
Chassis - Control Relays Greater than 8x1 or Control Multiple Relays in Series Forming Larger Switches than Normally Possible Such as 16x1 to 32x1 Sections.
CXM/256-MF
These Chassis are typically used to control relays greater than 8x1 or control multiple relays in series forming larger switches than normally possible such as 16x1 to 32x1 sections. Or control mixtures of 8x1"s, 4x1"s, 2x1"s and 2x2 modules in any combination or configuration for up to 256 relay drives. LEDs on the front panel show switch and power status. Add Switch Modules, display / driver modules and a Control Module to complete the system or simply buy the chassis wired out to D connectors to control your own relays. A manual control is optional.
-
product
8-Ch SPST 20A-250VAC High Current
YAV90087
8 power relays Switching 20A 250Vac PNP Outputs para control or YAV90304 control CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
PXI Flexible Microwave Module, Dual SP4T Terminated 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
40-890-002
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
(8×16)-Ch Dual Pole 2A-250VAC Matrix
YAV90060
128 relays DPST double matrix (4×16). Switching up to 250Vac and 2A CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
PXIe Flexible Microwave Module, Dual SP4T Terminated 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
42-890-002
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
PXI Flexible Microwave Module, Dual SP6T 26.5 GHz, Single SPDT 26.5 GHz, 50 Ω, SMA
40-890-003
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
PXIe Flexible Microwave Module, Dual SP6T 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
42-890-005
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
32-Ch SPDT 2A-240VAC 24VDC Switching
YAV90133
32 relays, 5A Switching 5A 250Vac. Up to 1250VA 28 Relays SPST Mux. 1 a 4 relays CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
(8×32)-Ch 0,5A-200VAC Matrix
YAV90062
256 relays SPST matrix (4×64 1 pole) or (4×32 2 poles). Max switching 10W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
Digital I/O Device
The Digital I/O Device supports channel, current, and voltage options to help you automate applications. This module features programmable input filters to remove chatter, noise, glitches, and spikes on inputs, and these filters also provide debouncing for digital switches and relays. You can use the module to perform safe operation when connected to pumps, motors, and other industrial actuators or machinery using the included power-up states. The module also provides a fail-safe mechanism that monitors for computer or application crashes and place the system in a state to ensure safe recovery. Additionally, some models include high-voltage, high-current, and isolation options to ensure the product can work safely in many environments.The Digital I/O Device includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
PXI Multiplexer Switch Module
PXI Multiplexer Switch Modules are ideal for high-channel-count applications that need to connect measurement or signal generation instruments to various test points on devices or units under test(DUTs or UUTs). PXI Multiplexer Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor(FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a multiplexer that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NISwitch Executive provides additional software tools to help you design, build, and deploy your switching system.
-
product
PXIe Flexible Microwave Module, Dual SP6T Terminated 26.5 GHz, Single SPDT 26.5 GHz, 50 Ω, SMA
42-890-004
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
product
PXI RF Matrix Switch Module
PXI RF Matrix Switch Modules are organized into rows and columns and provide maximum flexibility for switching systems by allowing you to connect any channel to any other channel. PXI RF Matrix Switch Modules use a variety of relay types, including electromechanical armature relays, reed relays, field-effect transistor (FET) relays, and solid-state relays, each with their own benefits, allowing you to choose a matrix that fits your requirements. To program the switches, you can use the IVI-compliant NI-SWITCH driver software, complete with help documentation, example programs, and a soft front panel application for interactive control of switches. For intelligent management of complex switch systems, NI Switch Executive provides additional software tools to help you design, build, and deploy your switching system.
-
product
(2×32)-Ch 1A-1500VDC 24VAC Matrix
YAV90097
32-Lines selectable High-Open-Low connection 3kV 1,0A Relays (Cool connection) Hipot test capabilities CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
Serial-to-Daq Card
Model 2307
* 2307 Board provides 32 digital I/O lines, 4 analog outputs, 6 analog inputs, 6 relay driver outputs and 4 temperature inputs.* Firmware supports ASCII command strings, Addressed commands for RS-485 networks and packet protocol. * Operates as a RS-232 as a RS-485 to Data Acquisition Board. * DE-9 connector has both RS-232 and RS-485 signals.* SCPI commands and IEEE 488.2 compatibility provide GPIB like operation over the serial link. * Runs on 5 Vdc power.