Filter Results By:
Products
Applications
Manufacturers
Oscilloscope Probes
probe with lead for single-ended measurements connected to ground.
See Also: Oscilloscopes, Analog Oscilloscopes, Digital Storage Oscilloscopes
- TEAM SOLUTIONS, INC.
product
HandyScope HS6-DIFF With SafeGround & SureConnect: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XMSG-W5
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.-SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
product
Current Probe For Oscilloscopes
CP 1005
The CP 1005 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
product
Oscilloscope, 200 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch DSO, Fully Loaded with 10.1" Color Display
T3DSO2204HD
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
product
HandyScope HS6-DIFF With SureConnect: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XMS-W5
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Hook Test Clip
PCM
The PCM Parrot hook Test Clip model is a small size hook test clip with a length of 70 mm, including the metal tip and the button.Due to this smaller size it is aimed to be used for many applications as oscilloscope ground, spectrum analyzers, data lodgers multimeter test leads and probes.
-
product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
product
Oscilloscope Tester
ScopeTester 5
ScopeTester 5 is 5-channel oscilloscope tester for PCs. Unlike traditional oscilloscopes it is capable of continuous acquisition of signals without dead times. This feature gives exceptional diagnostic value. Available voltage ranges matches typical signals found in modern cars. The user may connect to vehicle sensors, actuators and other diagnostic equipment, such as current clamps, inductive and capacitive probes and other diagnostic probes.
-
product
AC/DC Current Probe (2-Channel), 3 MHz, 50 UA
N2820A
The N2820A 2-channel current probe connects to two oscilloscope channels to provide simultaneous low- and high-gain views for wider dynamic range measurement, while the N2821A 1-channel current probe provides one user-selectable view at a time.
-
product
200 MHz, 3.5 pF, 1 MOhm Active Differential probe
ZD200
With the ProBus interface, the ZD200 becomes an integral part of the oscilloscope. The probe sensitivity and offset are automatically optimized based on the oscilloscope gain settings, so control is transparent to the user. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
Shaft Voltage Tester™ Digital Oscilloscope
AEGIS®
Digital Oscilloscope and Multimeter with Conductive Microfiber Probe Tips. Is your motor safe from destructive shaft voltages? For the first time you can get all of the tools to find out in one place. The AEGIS® Shaft Voltage Tester™ Digital Oscilloscope bundle includes the AEGIS-OSC-9100 100 MHz digital osciloscope, shaft voltage probe tips, and a shaft grounding simulator. Armed with these tools, you can quickly and easily find whether your motors are at risk of premature bearing failure due to VFD-produced bearing currents.
-
product
500 MHz Passive Probe for WaveJet Touch, 10:1, 10 MOhm
PP006D
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Oscilloscope Probe
An oscilloscope probe establishes a physical and electrical connection between a test point or source and an oscilloscope; in fact, an oscilloscope probe is a type of device or network that connects a signal source to an oscilloscope input.
-
product
Voltage Probes
An oscilloscope is only as good as its probes. Our range includes high voltage, differential, active, low capacitance, and passive types, with ranges to 30kV and frequency bandwidths to 5 GHz.
-
product
CC15010X, 10 MHz, 150 A Current Oscilloscope Probe
786849-01
The CC15010X, or Hioki 3274, is a clamp-on current probe that offers a wide DC to 10 MHz bandwidth and 150 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
NI-5191, 800 MHz, ±30 V, 10X Attenuation, Differential Active Oscilloscope Probe
781785-01
The NI-5191 is a differential, active voltage probe that offers 800 MHz of input bandwidth with a 10:1 attenuation ratio. You can use it with oscilloscopes that provide 50 Ω input impedance. You can power the probe using a Type-N barrel power connector from a USB port or using a 9 V alkaline battery.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP023-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Mixed Signal Oscilloscopes
Fully configured USB 2.0 oscilloscope - 14 bit 100 MSa/s, 2 analog channels, 8 digital inputs, External Trigger, 8M samples storage for each of the 2 analog and 8 digital channels, CS700 Signal Generator (0-10MHz, Sine, Square, Triangle). Complete with the CS300 application software, 2 x CS1001 and CS1004/5 probe sets. The front panel ground is continuous via the USB ground to the PC.
-
product
Probe Adapters
Probe adapters provide simple and easy interface of third-party probes as well as change between the different Teledyne LeCroy Oscilloscope input and cable types (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending on the adapters, changing between the Teledyne LeCroy Oscilloscope's input type may have an effect on the overall performance of the channel.
-
product
LXI WTB Probe, Terminated
60-981-002
The 60-981 LXI Wired Trigger Probe provides a simple method of monitoring the LXI Wired Trigger Bus activity. It provides a through line active probe that can be used to non-intrusively monitor the waveforms of the M-LVDS drivers on all 8 channels. Each channel has two single ended outputs from the differential pair that can be subtracted by an oscilloscope to display each driver output and the differential signal.
-
product
Sensor Unit for High Precision Current Sensors
CT9557
Hioki pull-through current sensors and clamp on current probes are best-in-class current sensing devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT9555 is 4-channel sensor unit and power adapter for any of the CT686x series, 9709 and CT684x series current sensors and probes that provides waveform and RMS output.
-
product
7.5 GHz Low Capacitance ÷10/÷20 probe
PP066
The PP066 is a high-bandwidth passive probe designed for the use with the WaveMaster™ and other high-bandwidth oscilloscopes that have 50 Ω input termination. This very low capacitance probe provides an excellent solution for higher frequency applications, especially the probing of transmission lines with 20–100 Ω impedance.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
2-Channel Oscilloscope DIY Kit
WAVE2
WAVE2 is the latest 2-Channel Oscilloscope on the market, catered to hobbyists, educational institutions and professionals in the field of electronics and mechatronics. Featuring a bright and easy-to-use color touch screen display with access to many features only advance oscilloscopes offer such as built-in function generator and X-Y plotting. With an optional battery, it is portable enough to be taken wherever the jobs that need to be done is. Its an exciting project for any DIY-er, or can be purchased fully assembled for those who are looking to start using it right away. It comes with everything you need to start using it right away, with a micro-USB cable and two high-quality BNC probes. Enjoy and start creating!
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Passive Probe, 10:1, 200 MHz, 2-Pack
N2140A
The Keysight N2140A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 200 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
product
10 KV High-Voltage Oscilloscope Probe, CTUVus Listed
CT4432
Because an oscilloscope has limits to the input voltage it can accept, measuring higher voltages may sometimes require the use of an attenuating high-voltage probe. The CT4432, with an improved dual-resistor design, can accurately and safely step-down higher voltages to an acceptable level.