Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Microwave Transfer Switch, Single, 18 GHz, 50 Ω, SMA, Failsafe, Remote Mount
40-782B-521-E
The 40-782B-521-E (PXI) and 42-782B-521-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 18 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
Frequency Large Display Indicator
Signals & Systems India Private Limited
Large Display indicator measures and displays frequency from the input like supply voltage, 4-20mA and data received from other equipment. It meets high accuracy of 0.1% to measure Frequency. The large display is for clear visibility of the frequency reading from long distance. It is equipped with high bright red color 7segment displays. These are commonly used in Power plants, Substations, Manufacturing units and Field environments to provide direct frequency measurements of various devices.
-
product
Single Frequency CW 532 NM Laser up to 18W
EQUINOX
Equinox is a single frequency, 532 nm continuous wave laser designed for a range of scientific applications including pumping any Ti:Sapphire laser systems. It is engineered to meet the needs of experimentalists requiring high-performance systems with an emphasis on reliability, stability and ease of use. The laser incorporates pump diodes within the central unit and is fully automated with hands-free operation and control via ethernet, webpage and TCP/IP remote interface. This completely sealed system is inherently stable with low noise levels <0.05 % RMS and ultra-stable output powers with ±0.5 % stability. Equinox has options of high output power up to 18 W. Other major applications include mixing source, pump source for dye lasers and frequency doublers, optical tweezers, and biomedical imaging.
-
product
Power Frequency Transducer
TDF
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C± 5 °C• High Dielectric Strength 2.6KV AC / Min, Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
product
Digital Instantaneous Frequency Measurement Receivers
DIFM
Mercury Systems offers a range of standard high-performance broadband Digital Instantaneous Frequency Measurement (DIFM) receivers and Digital Frequency Discrimination (DFD), which act as functional building blocks in many military electronic warfare systems. Examples include electronic counter measures (ECM) systems, electronic surveillance measures (ESM) systems and radar warning receivers (RWR).
-
product
Voltage Controlled Crystal Oscillators
VCXOS
Voltage Controlled Crystal Oscillators (VCXOs) are used for fine adjustment of the operating frequency and are normally used in conjunction with a phase locked loop.
-
product
InfiniiMax Probe, 3.5 GHz
1131B
Provides extremely low input capacitance, flat frequency response, and patented resistor probe tip technology.
-
product
OTA Power Measurement Solution
NRPM
The R&S®NRPM is a fully calibrated and individual scalable OTA power measurement solution for benchtop application or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz it is perfect for Over-the-Air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of the transmit antenna output power.
-
product
Sine-wave Vibro Viscometer
SV-10 Series
Newly developed Tuning-fork Vibration Method* promises you high accuracy and wide measurement range without replacing sensor plates!! *Patent pending. Sine-wave Vibro Viscometer SV-10/SV-100 measures viscosity by detecting the driving electric current necessary to resonate the two sensor plates at constant frequency of 30Hz and amplitude of less than 1mm.
-
product
Precision LCR Meter (20Hz to 1MHz)
ST2827
ST2827 series precision LCR meter has multiple functions and higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. ST2827 series is easy to operate with a 4.3-inch LCD screen as well as English operation interfaces. Integrated transformer test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.
-
product
MOSFETs
Products for a variety of applications, such as power supply, motor drive, high frequency amplification, and load switches.
-
product
RF Power Splitter, Combiner, Divider RoHS, 8 Way, Type-N Female, 698 - 2700 MHz, 50 Ohm
PD2080
INSTOCK Wireless Components, Inc
Wideband Frequency (698 - 2700 MHz)Low Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)RoHS Compliant Splitter ConstructionTri Alloy Type N Female (Jack) Low PIM
-
product
Comb Generator, 10 MHz To 110 GHz
U9391M
U9391M comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
product
Mobile Watt Meter
PM2000AM
The PM2000AM Mobile measures and displays forward power, reflected power, and SWR simultaneously on it's dual movement meter system in the frequency range. Accuracy of the readings is assured because the PM2000AM features a true shielded directional coupler, that on the mobile version is offered as an external unit. The backlit meter can display either peak or average power readings, and has 300 and 3000 watt range settings.
-
product
Signal Converters
On one hand, there are signal converters which transform an input frequency range into an analog signal. These signal converters are very easy to program and control. Other signal converters can transform analog input signals into analog normalized signals with galvanic insulation. Due to the fact that these signal converters can be freely graduated, they offer endless possibilities and 110 combinations can be selected by means of a DIP switch. Other kinds of signal converters can be connected to devices with RS-232, RS-485 or RS-422 protocols.
-
product
BAW Devices
Teledyne RF & Microwave has been producing Bulk Acoustic Wave (BAW) delay devices since the early 1960’s. Over the years,Teledyne has constantly improved BAW technology and is currently the world’s only supplier of microwave bulk acoustic wave delay devices. Markets for BAW devices include instrumentation and radar altimeters and are available in connectorized, pin and surface mount configurations.BAW devices operate as low as 300 MHz and as high as 17 GHz, usually in sub-bands of around 10%. Depending on the delay and frequency of operation the insertion loss is in the range 30 dB to 90 dB.
-
product
PXIe Microwave Signal Generator, 1 MHz to 44 GHz
M9383A
Modular test solution for design validation that can be efficiently leveraged into manufacturing Flexibility to solve your immediate test needs, but upgradable for what comes next – whether that’s upgrading for frequency coverage, or a rapid shift to high volume production.Pre-5G signal confidence you need with 1% EVM @ 28 GHz, 800 MHz bandwidth
-
product
DDS Function Generator, Digital Control 10MHz Or 20MHz, With/without USB/RS232 Interfaces
TG2000 Series
0.001Hz to 10MHz/20MHz frequency range6 digits or 1mHz resolution1ppm stability and 10ppm one year accuracyLow distortion, high spectral purity sine wavesInternal phase continuous sweep, lin or logAM, FSK, gated and tone switching modes5mV to 20V pk-pk from 50 or 600 OhmsStorage for multiple instrument set-upsUSB and RS232 Interfaces (TG2000 only)
-
product
Intelligent Handheld Power Meter
TW3206
Techwin(China) Industry Co., Ltd
TW3206 intelligent handheld power meter is a perfect testing instrument for both laboratory and field applications in optical fibers. It features friendly User Interface with menu operation, automatic frequency identification , large LCD display with backlight and dual-way powering system. The internal microprocessor and linear amplifier technology ensure the long-term accuracy. In addition, TW3206 has a memory capacity of 240 records and can transfer the measurement data through a RS232 communication port to a PC for printing or editing. Moreover, it can also perform on-line data upload after programme control.
-
product
FieldFox Handheld Microwave Analyzer
N9913A
4 GHz max frequency Carry the world's most integrated handheld RF analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without warm-up Calibrate simply with QuickCal Lightest all-in-one analyzer at only6.6 lb. (3.0 kg) Industry-leading 3 year warranty Every spec verified, adjustments included Lock in support & peak performance from the start
-
product
PXI/PXIe Microwave Transfer Switch, Single, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
40-782B-541-E
The 40-782B-541-E (PXI) and 42-782B-541-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
product
Low Frequency Generator
LFG-2500
• tracing – finding the route and burial depth of the underground utilities;• fault location – pinpointing phase-to-sheath and interphase short-circuit faults;• cable identification – identifying a correct cable in a bunch.
-
product
One Phase Electric Power/Energy Calibrator
MC133
The MC133 master unit model is a one phase electric power/energy calibrator. It can supply the device under test with single phase precise voltage and current with calibrated phase shift along with DC voltage and current capability. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. Simulated electric power can be set independently for each phase. Frequency can be set from 15Hz to 1 kHz with resolution 0.001Hz to 0.01Hz. The MC133 Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20mA or 10V for direct calibration of various types of power transducers and wattmeters.
-
product
Ytterbium-doped Fiber Amplifier
YDFA
Ytterbium-doped Fiber Amplifier (YDFA) is another Amonics specialised product line. Like our highly recognized optical amplifiers, the YDFA offers high output power and high gain with exceptional reliability. ideal for high power YDFA applications. The turnkey microprocessor controlled benchtop YDFAs manage alarms and status indicators. An integrated RS232 or Ethernet computer interface enables easy control, diagnostic functions and data acquisition. Available options include single frequency operation, linearly polarized operation.
-
product
SWR / Power Meters
SX200
Frequency range:1.8 to 200MHz. Power display range:5W 20W 200W. Accuracy at full scale:5W Range ±5%(F.S),20W Range ±7.5%(F.S),200W Range ±5%(F.S), (Add +15% of full scale at 160 to 200MHz). Minimum power at SWR
-
product
Miller 400D
44550
No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)
-
product
Radar Front Ends (FMCW)
FMCW Series
Farran’s 77 GHz FMCW Radar front end is based on a GaAs MMIC chipset offering wide bandwidth in a small outline package.The transmit signal is derived from an external VCO signal, internally multiplied, which also acts as the LO for the receive mixer. The resulting IF is conditioned for gain and filtering as required. The IF also contains an industry leading IF noise figure, especially in the frequency range below 500MHz. Custom designs available, visit our custom design page for more information.
-
product
Hardy Shaker
HI-913
This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.
-
product
Precision Impedance Analyzers
6500B Series
Accurate high frequency measurements combined with an easy to use graphical interface and high resolution colour display.
-
product
Ultrasonic Leak Detector
SE-7001
Frequency Response:36kHZ—44kHZ(Centered at 40kHz)Indicator: LED and EarphoneOperating Temperature: 0℃ to 40℃Operating Humidity: <80%RHStorage Temperature: -10℃ to 40℃Power supply: 9V alkaline batteryWeight: 125.5gDimensions:150mm(L)X90mm(W)X50mm(H)
-
product
Micsig Ocilloscope AC Current Probe
ACP1000
Shenzhen Micsig Instruments Co., Ltd.
*Test Current Range: 0.1A-1000A*Operating Frequency: 10Hz-100kHz*Maximum Primary Current: 2000A (2s)*Output Signal: mV/A*Highest Precision: 1%