Langer EMV-Technik GmbH
Langer EMV-Technik GmbH is a medium-sized electro-technical company which is active in the field of electromagnetic compatibility-related
- +49 (0) 351 430093-0
- +49 (0) 351 430093-22
- mail@langer-emv.de
- Nöthnitzer Hang 31
Bannewitz, D-01728
Germany
-
product
Near Field Microprobe E-field 7 MHz to 3 GHz
ICR E150
The near field microprobe is used to measure electric fields at extremely high resolution and sensitivity. The optimal distance to the object being measured is < 1 mm. Due to its small probe head dimension, the probe has to be moved by a manual or automatic positioning system, e.g. Langer-Scanner.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF6 set
The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Near Field Micro Probe Sets
The near field probe is designed for a high-resolution measurement of electrical near fields.
-
product
MP field sources calibration set
The MP field source calibration set is used to measure electric or magnetic fields in a frequency range up to 3 GHz. RF fields or transient fields can be measured. The MP field source calibration set is used to check fields of the Langer EMV-Technik GmbH field sources, fields of TEM cells and IC striplines.
-
product
Optical signal transmission
Digital
The fibre optic cable are used to transmit digital signals from the device under test under EFT/burst interference.
-
product
Near Field Probes
MFA Family
The micro probes allow detailed measurements of high-frequency magnetic fields in the layout, at the smallest SMD components(0603-0201) and at IC pins of printed circuit boards.
-
product
Immunity
ESD coupling
is used for conducted coupling of Langer ESD pulses (200ps rise time) into ICs.
-
product
Preamplifier
Is designed for the amplification of measuring signals, e.g. weak signals of near field probes with high resolution.
-
product
Near Field Probes 1GHz - 10 GHz
SX set
The SX1 set consists of 3 passive near field probes for making measurements in the development phase of E-field and magnetic field with a high clock frequency in the range from 1 GHz to 10 GHz. The probe heads of the set SX allow for measurements close to electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors, to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through trained use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF1 set
The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Immunity Development System
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
product
Optical Signal Transmission
Analog
Used for oscillographing analog signals under EFT/EDS/RF interference.
-
product
Near Field Micro Probe ICR HV H Field
The measurement coil is located vertically in the probe head. The near field probes are run with a positioning system (Langer Scanner).
-
product
Measurement Technology for the Development Stage
EMC tools for relative measurements of interference emission of assemblies and devices.