Shimadzu Corp.
Shimadzu Corporation has remained committed to commercializing cutting-edge technology and providing it to customers in a wide array of industries for more than 140 years. Our brand statement, "Excellence in Science", reflects our desire and attitude to diligently respond to customers' requirements by offering superior, world-class analytical and measuring instruments, medical imaging systems, aircraft equipment and industrial machinery for the advancement of human health, the safety and security of society, and industrial processes. In today’s challenging, ever-changing landscape, Shimadzu aims to partner with customers to meet their needs with unique technologies and solutions.
- 81-75-823-1111
- 1 Nishinokyo Kuwabara-cho
Nakagyo-ku
Kyoto, 604-8511
Japan
-
product
EDXIR-Analysis Contaminant Finder/Material Inspector
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues identification results and the degree of matching. it can also be used to perform EDX or FTIR data analysis on its own. The library used for data analysis (containing 485 data as standard) is original to Shimadzu, and was created through cooperation with water supply agencies and food manufacturers. Additional data can be registered to the library, as can image files and document files in PDF format. It is also effective for the linked storage of various types of data as electronic files.
-
product
Bending Deflectometers For ISO 178, JIS K 7171, And ASTM D790 Compliant Testing
After tensile testing, flexural tests are the most common strength tests for plastics and other resins. The main standards for plastic flexural (bend) tests are ISO 178, JIS K 7171, and ASTM D790, which require very accurate test systems. These standards include flexural strain measurements using a deflectometer, ranging from micro-strain measurements in the elastic region, the reversible elongation at the beginning of tests, to larger strain measurements in the plastic region. Shimadzu's deflectometers integrate easily into AG-X plus series, AGS-X series, and EZ-X test frames and Trapezium X testing software. Since these deflectometers push up against the specimen from below, the specimen color is not a limiting factor, as can be for laser type non-contact deflectometers. Furthermore, these deflectometers can partially absorb the shock during specimen failure, preventing specimen fragments from scattering.
-
product
Protein Sequencer
PPSQ-51A/53A
The PPSQ is an instrument for determining the amino acid sequences of proteins and peptides, which combines an Edman reaction section with a high performance liquid chromatograph (HPLC). There are 2 types: the PPSQ-51A, which is equipped with one reactor, and the PPSQ-53A, which is equipped with three reactors. On the PPSQ-53A, the continuous analysis of the amino acid sequences of multiple samples can be performed one after another. In the Edman reaction section, amino acids are cleaved in order from the N-terminal of a protein by repeatedly performing Edman degradation, and are derivatized. As a result, stable PTH-amino acids are produced. The PTH-amino acids are injected online into the HPLC, and analysis is performed. The HPLC data is saved on the PC, and data processing software is used to process the chromatograms. Then, amino acid sequence estimation software is used to identify the amino acids and estimate the sequences.
-
product
Axial Force And Torsion Testing Machine
Evaluation Testing That Approximates Operating Conditions of Materials and Parts - Loading methods similar to actual usage - Allows simultaneous application of axial and torsional loads to samples
-
product
Material Testing Software
TRAPEZIUM X
Windows 10 compatible TRAPEZIUM X can carry out various tests ranging from simple test control to complex custom-made patterns, using the industry's first data search and preview function, free layout reports, visual wizard settings, quick panel, and quick conditions lists.
-
product
Material Testing Software
TRAPEZIUM LITE X
Simple Software Enhances Productivity TRAPEZIUM LITE X is newly developed simple software for Autograph series testing machines. It boasts comprehensive new functions for more efficient testing.
-
product
Principle Of MALDI/TOFMS
MALDI is the abbreviation for "Matrix Assisted Laser Desorption/Ionization." The sample for MALDI is uniformly mixed in a large quantity of matrix. The matrix absorbs the ultraviolet light (nitrogen laser light, wavelength 337 nm) and converts it to heat energy. A small part of the matrix (down to 100 nm from the top outer surface of the Analyte in the diagram) heats rapidly (in several nano seconds) and is vaporized, together with the sample.
-
product
Type 1 And Type 2 Pantograph Grips
Pantograph grips use a simple spring design to hold and apply pressure to specimens during tensile testing. These grips are mainly used for tensile testing plate specimens of rubber, textiles, or soft plastics.
-
product
LabSolutions Insight Library Screening
LabSolutions Insight Library Screening is optional software for LabSolutions Insight. This software helps with Screening Target Components.
-
product
8-Port Sampler For TOC-V
OCT-1
Bringing you an innovative but inexpensive auto sampler that automates your analyzer system.Setup is extremely easy, because special vials are not needed.
-
product
Workstation Software For Thermal Analyzer
LabSolutions TA
A new design and enhanced functions that can be used at a glance. Intuitive operations that allow seamlessly performing the sequence of processes from measurement to analysis, and the outputting of reports.
-
product
Evaporative Light Scattering Detector
ELSD-LTII
The ELSD-LTII utilizes a high-efficiency LED and enhanced digital signal treatment to minimize noise and deliver optimum sensitivity for trace analysis. An innovative cell design also reduces band broadening and allows sensitivity levels below 200 picograms. The high-performance optical detection system can also be used for combinatorial chemistry and high-throughput screening applications. The new Low Temperature Evaporative Light Scattering Detector (ELSD-LTII) is an easy-to-operate, universal detector that identifies analytes with uniform sensitivity regardless of their spectroscopic properties. It is not a spectroscopic detector. Instead, it removes the mobile phase through evaporation and then makes a light scattering measurement of the dried analyte particles.
-
product
LC Software
LabSolutions LCGC
With LabSolutions, both LC and GC systems are operated from the same software, enabling simultaneous control of multiple instruments from a single PC. The LC and GC instruments connected can be used in a flexible manner by switching between them. The shared LC and GC analysis operating environment, which inherits the operability of LCsolution and GCsolution, lessens the training time for workstation operations.
-
product
Energy Dispersive X-ray Fluorescence Spectrometer
Pharmaceutical Elemental Impurities Analysis System
Control of Elemental Impurities in Pharmaceuticals In the pharmaceutical industry, the analysis of elemental impurities is necessary to ensure the safety of pharmaceuticals. In December 2014, the "Guideline for Elemental Impurities" (Q3D) was issued by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH), consisting of representatives from Europe, the U.S. and Japan. In Japan, the "Guideline for Elemental Impurities in Drug Products" (PFSB/ELD Notification 0930 #4 from the Ministry of Health, Labour and Welfare) was issued, and will be applied to new drug products submitted for approval after April 1 2017. For 24 elements categorized in Class 1 to Class 3, residual quantities in pharmaceutical drug products must be controlled within permissible limits. Although ICP-AES and ICP-MS are used for precise analysis of elemental impurities, X-ray fluorescence spectrometers can be used as an alternative analysis method. This is because they can quantitatively and qualitatively analyze a variety of elements nondestructively, and without chemical pretreatment, unlike ICP-AES and ICP-MS systems. The X-ray fluorescence spectrometry has been adopted as a general method of analysis in the U.S Pharmacopeia and the European Pharmacopoeia. (USP<735>, Ph.Eur.2.2.37)
-
product
UV-VIS-NIR Spectrophotometer
UV-2600i, UV-2700i
The compact UV-2600i/2700i is a universal, research-grade spectrophotometer that can be used in a wide range of fields, and easily expanded to suit the measurement objective. By using the optional integrating sphere, the measurement wavelength range of the UV-2600 can be extended to the near-infrared region of 1400 nm. The UV-2700 is capable of 8-Abs measurements, and optimal for measuring low transmittance samples.